en Display
Display
1
E:35 / -10
1
Example
22
Designation
Energy consump-
tion
Water consump-
tion
End signal
Button signal
Display brightness Basic setting
Reminder to clean
the drum
Voltage control
system
Voltage control
system
Foam detection
system
Door
Tap
Error
More information
Energy consumption for the selected pro-
gramme.
: Low energy consumption
¡
: High energy consumption
¡
Water consumption for the selected pro-
gramme.
: Low water consumption
¡
: High water consumption
¡
Basic setting
Basic setting
Flashes: Drum is dirty. Run the Trum-
rengöring programme for cleaning and
caring for the drum and the outer tub.
→ "Cleaning the drum", Page 42
Flashes: The automatic voltage control
system detects impermissible voltage
drops. This will pause the programme.
Note: The programme will continue when
the voltage is permissible again.
Flashes: The programme has been
paused because of impermissible voltage
drops. The voltage is permissible again
and the programme will continue.
Note: The programme duration is exten-
ded.
The appliance has detected too much
foam.
¡ Lights up: The door is locked and can-
not be opened.
¡ Flashes: The door is not closed prop-
erly.
¡ Off: The door is unlocked and can be
opened.
¡ No water pressure.
¡ The water pressure is too low.
Error code, error display, signal.