Hargrove LCK-RC Installation Instruction page 2

Gas log latchtap kit

Advertisement

WARNING: If you do not follow these instructions exactly, a fire or explosion may occur
resulting in property damage, personal injury, or loss of life.
THIS APPLIANCE HAS A PILOT, WHICH MUST BE LIT BY HAND. WHEN LIGHTING THE PILOT, FOLLOW THESE
INSTRUCTIONS EXACTLY. BEFORE LIGHTING, SMELL ALL AROUND THE APPLIANCE AREA FOR GAS. BE
SURE TO SMELL NEXT TO THE FLOOR BECAUSE SOME GASES ARE HEAVIER THAN AIR AND WILL SETTLE
ON THE FLOOR.
BASIC OPERATION
1. Knob is for manual pilot, on-off function. Turn knob counterclockwise to the "PILOT" position and depress knob to
allow flow of the pilot gas to the pilot burner. See Figure 2
*USE ONLY YOUR HAND TO TURN OR PUSH IN KNOB! Never use tools. If the knob will not push in or turn by
hand, do not try to repair it. Call a qualified service technician. Forced or attempted repair may result in a fire or
explosion.
2. Light the pilot and continue to depress the knob for approximately thirty seconds. Release the knob and affirm that
the pilot flame is still present. If the pilot flame extinguishes, repeat steps 1 and 2 again, this time depress knob for
one minute. If pilot flame still extinguishes upon releasing the knob, assure than the thermocouple connection is tight.
Repeat steps 1and 2 again. If the pilot flame still extinguishes upon releasing the knob, call your service
f i r e - p a r t s . c o m
technician/dealer.
3. Upon lighting the pilot, continue to turn the knob counterclockwise toward the "FULL ON" position until desired flame
height is reached.
IMPORTANT: GAS WILL NOT FLOW TO THE EMBER BURNER UNTIL THE LATCHTAP (CLC-BLOCK) IS
ENGAGED USING ON OF THE SWITCHING DEVICES (REMOTE CONTROL, BARK CHIP SWITCH OR WALL
SWITCH)
REMOTE OPERATION OF LATCHTAP SYSTEM
1.
Once desired flame height is set, the burner can be turned off or on using one of the Switching Device shown below
(See Remote Control box for "Remote Installation Instructions"). If using the Remote Control it is recommended that
the remote receiver be located outside the fireplace. The latchtap system uses a solenoid valve to turn the gas flow to
the burner on or off. The burner may also be operated manually using the knob. Turn the Knob counterclockwise to
increase flame height and clockwise to decrease/shut off-the flame.
Remote Control
(RC-S6V-LT)
SHUT-OFF PROCEDURE
Turn Knob (Figure 2) clockwise until reaching stop. Press down slightly and continue turning clockwise from "PILOT"
1.
position to the "OFF" position.
*Very high-pressure gas surges may result in internal damage or leaks. If you suspect your control has been exposed
to more than 1 1/2 times its maximum, have the unit checked by an expert.
OPERATION INSTRUCTIONS
FOR YOUR SAFETY
Battery Powered Bark Chip
(BPBCS)
Battery Powered
Wall Switch
(WG-WS)
Battery Powered
Wireless Wall Switch