Electrical Connection - Miele ESW 6114 Operating And Installation Instructions

Gourmet warming drawer
Table of Contents

Advertisement

Electrical connection

48
All manuals and user guides at all-guides.com
All electrical work should be carried out only by a suitably
qualified and competent person in strict accordance with
national and local safety regulations.
The appliance is supplied with a mains cable with moulded
plug for connection to a 230 V mains supply.
If the connection cable is damaged, it must be replaced with
a special connection cable of type H 05 V V-F (pvc
insulated), available from Miele.
The voltage and rated load are given on the data plate.
Please ensure these match the household mains supply.
Connection should be made via a switched socket which is
easily accessible after installation. For extra safety it is
advisable to install a residual current device (RCD), with a trip
current of 30 mA. Do not connect via an extension lead.
WARNING
THIS APPLIANCE MUST BE EARTHED

Advertisement

Table of Contents
loading

This manual is also suitable for:

Esw 6214Esw 6129Esw 6229

Table of Contents