Zoeller 64 HD Series Repair Manual

Zoeller 64 HD Series Repair Manual

Heavy duty solids handling pumps

Advertisement

Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
Register your
Zoeller Engineered Product
on our website:
http://reg.zoellerengprod.com/
64 HD SERIES HEAVY DUTY SOLIDS HANDLING PUMPS
Since 1939 the name Zoeller has represented the standard for
submersible dewatering and sewage pumps. The same high quality
workmanship and easy maintenance design has been incorporated into
this line of heavy-duty solids-handling submersible sewage pumps.
This manual incorporates the parts list and repair instructions into
one document to aid in the ownership of a Zoeller submersible non-clog
wastewater product. Please read and review this manual before repairing

Table of Contents

Safety Instructions ....................................................................... 1
Replacement Parts List ............................................................2-3
Disassembly Procedures ............................................................. 4
Assembly Procedures ...............................................................5-6
Pump Wiring Diagram .................................................................. 7
Service Checklist .......................................................................... 8
To Order Replacement Parts
PLEASE FURNISH THE FOLLOWING INFORMATION:
• Model Number
• Part Number of Pump
• Serial Number
• System Voltage
• Replacement Part Number and Description (refer to pages 2 & 3).
Short Term Storage
Storage of six months or less will not damage the submersible pump.
However, to ensure the best possible protection, the following is
advised:
• Store pump inside whenever possible or cover with some type
of protective covering.
• Tape or seal in plastic bag the terminal ends of wire leads.
• Spray coat unpainted surfaces with rust-inhibiting oil.
• See ZM3014 Owner's Manual before start-up.
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624
REPAIR MANUAL
© Copyright 2019 Zoeller
Co. All rights reserved.
®
1
the product. Follow the steps and procedures listed on ZM1074 for a
proper start-up upon installation. Many items contained within, when
followed correctly, will not only ensure a long and problem-free life for
the pump, but also save time and money during installation. Reference
ZM3014 for owner's manual on 64 HD Series Pumps. Should further
assistance be necessary please call our Product Support Department
at 1-800-928-PUMP (7867).

Safety Instructions

TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MA-
JOR PROPERTY DAMAGE, READ AND FOLLOW ALL SAFETY
INSTRUCTIONS IN THIS MANUAL AND ON THE PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE INSTALLATION
AND OPERATION OF THIS UNIT AND MUST BE KEPT WITH
THE PUMP.
This is a SAFETY ALERT SYMBOL.
When you see this symbol on the pump or in the
manual, look for one of the following signal words
and be alert to the potential for personal injury or
property damage.
Warns of hazards that WILL cause serious personal
injury, death or major property damage.
Warns of hazards that CAN cause serious personal
injury, death or major property damage.
Warns of hazards that CAN cause personal injury
CAUTION
or property damage.
INDICATES SPECIAL INSTRUCTIONS WHICH ARE
VERY IMPORTANT AND MUST BE FOLLOWED.
THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS
PRIOR TO PERFORMING ANY WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.
SECTION: Z2.30.170
Visit our web site:
zoellerengineered.com
ZM3013
0119
Supersedes
0517

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 64 HD Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Zoeller 64 HD Series

  • Page 1: Table Of Contents

    Reference This manual incorporates the parts list and repair instructions into ZM3014 for owner’s manual on 64 HD Series Pumps. Should further one document to aid in the ownership of a Zoeller submersible non-clog assistance be necessary please call our Product Support Department wastewater product.
  • Page 2 SK3142 © Copyright 2019 Zoeller Co. All rights reserved. ®...
  • Page 3: Replacement Parts List

    O-Ring 281 007128 If pump was equipped with Pump Housing 4” or 6” Discharge SEE JOB FILE a trimmed impeller, consult Pipe Nipple 007133 factory. Pipe Cap 007406 Resistor 013740 © Copyright 2019 Zoeller Co. All rights reserved. ®...
  • Page 4: Disassembly Procedures

    Pry the lead wire housing (19) off using two screwdrivers. B. When removing impeller (42)... Complete Section A. Remove the eight screws (22) and lock washers (23) from the flange of the motor housing (20). © Copyright 2019 Zoeller Co. All rights reserved. ®...
  • Page 5: Assembly Procedures

    3. Install the seal ring (14) on the lead wire housing (12). 4. Connect lead wire terminals to motor lead terminals in the proper arrangement as per wiring diagram using screws (16) and nuts (18) and shrink tubing (17). Place shrink © Copyright 2019 Zoeller Co. All rights reserved. ®...
  • Page 6 (such as the cavity around the lower rotary seal), 2. Install the pipe plug (21). © Copyright 2019 Zoeller Co. All rights reserved. ®...
  • Page 7: Pump Wiring Diagram

    MOISTURE PROTECTION IS STANDARD NOTE 1 ON ALL EXPLOSION PROOF MOTORS ON PUMPS WITH 4 LEAD SENSOR CABLES: GREEN AND RED ARE THERMAL SENSORS, BLACK AND WHITE LEADS ARE MOISTURE SENSORS © Copyright 2019 Zoeller Co. All rights reserved. ®...
  • Page 8: Service Checklist

    - Abrasive material & chemical, deteriorated impeller and pump housing If the above check list does not uncover the problem, consult the factory - Do not attempt to service or otherwise disassemble pump. © Copyright 2019 Zoeller Co. All rights reserved. ®...

This manual is also suitable for: