Zoeller 6161 Owner's Manual

Zoeller 6161 Owner's Manual

Commercial duty pumps

Advertisement

Quick Links

Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
Register your
Zoeller Engineered Product
on our website:
http://reg.zoellerengprod.com/
EFFLUENT
6161, 6163, 6165
6185, 6186, 6188, 6189

Table of Contents

Safety Instructions ....................................................................... 1
Limited Warranty .......................................................................... 2
Preinstallation Checklist .............................................................. 2
Electrical Data ............................................................................3-4
Typical Installation ....................................................................... 4
Pump Wiring Instructions .........................................................5-6
Operation ....................................................................................... 7
General Maintenance ................................................................... 8
Service Checklist .......................................................................... 8
Owner's Information
Model Number: ______________ Date Code: _______________
 Simplex
Job Name: ____________________________________________
Distributor: ____________________________________________
Date of Purchase: _________ Zoeller S/O No.: ______________
Contractor: ____________________________________________
Date of Installation: _____________________________________
System Readings During Start-up: Voltage _____ Amps ______
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347 USA
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961 USA
+1 (502) 778-2731 • FAX +1 (502) 774-3624
OWNER'S MANUAL
Commercial Duty Pumps
Duplex
© Copyright 2017 Zoeller
SEWAGE
6282, 6284
6292, 6293, 6294, 6295
6404, 6405

Safety Instructions

TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR
PROPERTY DAMAGE, READ AND FOLLOW ALL SAFETY
INSTRUCTIONS IN THIS MANUAL AND ON THE PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE INSTALLATION
AND OPERATION OF THIS UNIT AND MUST BE KEPT WITH
THE PUMP.
This is a SAFETY ALERT SYMBOL.
When you see this symbol on the pump or in the
manual, look for one of the following signal words
and be alert to the potential for personal injury or
property damage.
Warns of hazards that WILL cause serious personal
injury, death or major property damage.
Warns of hazards that CAN cause serious personal
injury, death or major property damage.
Warns of hazards that CAN cause personal injury
CAUTION
or property damage.
Indicates special instructions which are very important
and must be followed.
THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS
PRIOR TO PERFORMING ANY WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.
REFER TO WARRANTY ON PAGE 2.
Co. All rights reserved.
®
50/60Hz
visit our web site:
zoellerengineered.com
L U
R
Tested to UL
Standard UL778 *
* NOTE: Applicable to 60 Hz units only.
ZM2670_Ec
0917
Supersedes
0417
R
Certified to CSA
Standard C22.2 No. 108
and Tested to UL
Standard UL778 *

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 6161 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Zoeller 6161

  • Page 1 Job Name: ____________________________________________ PRIOR TO PERFORMING ANY WORK ON THIS PUMP. Distributor: ____________________________________________ MAINTAIN ALL SAFETY DECALS. Date of Purchase: _________ Zoeller S/O No.: ______________ Contractor: ____________________________________________ Date of Installation: _____________________________________ REFER TO WARRANTY ON PAGE 2. System Readings During Start-up: Voltage _____ Amps ______ ©...
  • Page 2 Note: Pumps with the "UL" mark and pumps with the "US" mark are tested to UL pools and marine areas. standard UL778. CSA certified pumps are certified to CSA Standard C22.2 No. 108. © Copyright 2017 Zoeller Co. All rights reserved. ®...
  • Page 3 I6292 3450 19.8 3.59/2.94* * Line to line reading will only reflect the run winding resistance. Start winding resistance can only be measured after removing the cover. CONTINUED ON NEXT PAGE © Copyright 2017 Zoeller Co. All rights reserved. ®...
  • Page 4 (1) Pumps with power cord length less than 10 m (33') are intended for indoor use only. (2) Electrical wiring and protection must be in accordance with governing electrical codes ALARM LIGHT and any other applicable electrical requirements. (3) Install proper Zoeller Unicheck (combination union and check valve), preferably ® ELECTRICAL ALTERNATOR just above the basin, to allow easy removal of the pump for cleaning or repair.
  • Page 5 (3) Oil in the motor housing and lower seal cavity must be checked when pump is serviced. If oil from the motor housing contains water or other contaminations, both seals should be replaced during maintenance. Always replace with new factory-recommended oil and service parts. All warranty repairs must be made by an authorized Zoeller representative.
  • Page 6 ON position.Note: reseting the the dial with power applied to the motor protective switch could start the motor. Suitably rated disconnection means shall be incorporated in the fixed wiring in accordance with applicable codes. All wiring shall be done by qualified personnel according to all applicable codes. © Copyright 2017 Zoeller Co. All rights reserved. ®...
  • Page 7 If pump is used in water contaminated with heavy, viscous, manual for future reference. or abrasive materials, the warranty will be voided. After the preoperational functional test has been completed, system is ready for operation. Zoeller recommends completing a Start-up NAMEPLATE DATA ®...
  • Page 8 NOTE: for CE-rated pumps only. We, Zoeller, declare under our sole responsibility that the models 6161/6163/6165/6185/6186/6188/6189/6282/6284/6292/6293/6294/6295 to which this declaration relates, are in conformity with the Council Directives on the approximation of the laws of the EC Member States relating to:...

This manual is also suitable for:

616361656185618661886189 ... Show all