Download Print this page

Siruba VC008 DVU1-0 Parameter Manual page 15

Electronic control parameter manual

Advertisement

故障排除
錯誤碼
錯誤內容
Error
Error content
code
找不到停針位
Er01
Can´t find the needle
position
開機沒有檢測到調速器
Er02
Not detected boot
speed regulator
電機霍爾或相位線錯誤
Er03
Motor holzer or phase
error
堵轉保護
Er04
Locked-rotor protection
硬體過流保護
Er05
Hardware over-current
protection
串口通信逾時錯誤
Serial port
Er07
communication
timeout error
ERROR CODE & TROUBLE
SHOOTING
錯誤問題的多種可能
Several possible error problem
1. 手輪靠的不夠近間隙在 2.5mm 內
2. 九針插頭接觸不良
3. 電機霍爾壞,要更換電機
4. 手輪上的磁鐵掉落
1. The hand wheel is not close, clearance within 2.5 mm
2. Nine plug contact undesirable
3. Motor holzer bad, to replace the motor
4. The hand wheel magnet in the loss
1. 調速器插頭沒有插
2. 調速器線斷了或接觸不良
1. Speed control device without plug
2. Speed wire is broken or contact undesirable
1. 九針插頭接觸不良
2. 電機沒有安裝好,參照圖 A
3. 霍爾壞
1. Nine hole plug contact undesirable
2. The motor doesn´ t pack good
3. Holzer is bad
1. 電機超載
2. 電機與電控相連接的四心線接觸不好
3. 電機斷線或壞了
1. The motor overload
2. The motor and the controller connected four hole line contact is
not good
3. Motor is bad
1. 電機超載
2. 信號線接觸不好或斷了
3. 主機板壞了
1. The motor overload
2. Line contact is bad or broken
3. Main board is bad
顯示幕至主機板信號線不良或主機板壞
Display to the system board signal is bad or board is bad
Introduction
P12

Advertisement

loading

This manual is also suitable for:

Vc008 dvu1-0 f3x2