後抬腳啟動時間
P-31
back foot presser lifter
start time
抬壓腳動作維持時間
P-32
foot presser lifter
action maintain time
抬壓腳全力功率時間
P-33
foot presser lifter full
power time
抬壓腳全力功率時功
P-34
the power when the
foot presser lifter full
power
抬壓腳維持功率
P-35
foot presser lifter
maintain power
抬壓腳釋放時間
P-36
foot presser lifter
release time
抬壓腳保護時間
P-37
foot presser lifter
protection time
顯示速度
P-38
display time
顯示速控器電壓
P-39
display the volt of
speed controller
顯示直流母線電壓
P-40
display DC buses
voltage
過壓保護開關
P-41
overload protection
switch
P11
0-2000ms
0
50-1000ms
160ms
35-1000ms
160ms
5-100%
100%
1-500%
20%
0-120ms
30ms
1-100s
10s
200-4000RPM
中點電
壓 195
14-1010
Neutral
point
volt
60-500V
320v
0: 關閉 1: 開啟
1
0: close 1:start
後踏延遲啟動壓腳的時間
the time of back step delay
start foot presser
此參數暫時不用 this
parameter do not use now
壓腳釋放時間 the foot presser
lifter release time
壓腳單次抬起最大維持時間
the biggest maintain time of
the foot presser lifter single
time
顯示當前電機實際速度
display the current motor real
speed
顯示當前速控器電壓 0—
1024,相當於 0-5V
Display the current speed
controller volt 0-1024, it is
equal 0-5V
當電壓高於 395 會報警,( 直
流母線電壓 /1.414= 交流母線
電壓 )
when the volt is higher than
395V will alarm,(DC buses
volt/1.414 = AC buses volt )
設為 0 關閉過壓報警,設為 1
打開報警,當直流母線電壓超
過 395V 時,報警 Er16,電機
自動停止運行,報警後當電壓
低於 385v 電機可再次運行
set "0" is close the overload
alarm, set "1" is open the
alarm, when DC buses voltage
is over 395 V , will display
Er16, the motor will stop
automatic, when volt is lower
385V, the motor can run.