FUNCTION TIPS
AUDIBLE ALERTS
The OPM1 emits an audible beep each time a major function is used. To disable most beeps, ensure that the
unit is OFF. Press and hold the Save button, and turn the unit ON while holding the Save button. Perform the
same procedure to turn the audible beeps back on.
CONTINUOUS USAGE MODE
The OPM1 turns off automatically if no buttons are pressed for 5 minutes. To bypass this feature, hold the
Power button for 3 seconds when powering on. A series of beeps will indicate that the unit is now in
Continuous Mode and will not turn off automatically.
REVIEWING SAVED READINGS
While in the RCL mode, use the Save and Wavelength buttons to navigate through the saved readings on
the device. Each reading has a "location" indicated by a 4-digit number. Note the blue arrows on the Save
and Wavelength buttons. The data cycles at either end. Scrolling "up" from the last data point will cycle back
to the first location (0001) and vice versa.
DELETING SAVED READINGS
Press and hold the Save and Wavelength buttons simultaneously to delete all saved readings in the OPM1's
internal memory. The screen flashes 0000 to indicate that the memory is empty.
NON-VOLATILE MEMORY
The OPM1 uses a non-volatile memory system. Data is not lost if the unit is turned off while testing, if the
battery is removed, or if the unit is stored for long periods of time.
USB DOWNLOADS
Before transferring data from the OPM1 to the computer, download and install the SWIFT brand software,
available online at uclswiftna.com
Plug the OPM1 into the computer using the included USB cable. If this is the first time it has been
plugged in, wait at least ten seconds for the drivers to install.
Place the SWIFT brand software into Dump/Sync mode by navigating to Settings > Data Mode > Dump Mode.
Press the USB button on the OPM1 to dump/sync all data points. The data from the OPM1 appears in
the box on the left side of the window.
Fill out the fields on the right side of the window (Customer, User, Test Site, etc).
Navigate to Settings > Report Settings to identify a minimum and maximum value for the PASS/FAIL
functionality. Choose a color code scheme from this window, if necessary.
To create the final report, click File > Export to Excel.