UCL SWIFT TEK-4 Training Manual

Swift test kit

Advertisement

Quick Links

SECTION ONE: LSSM
SECTION TWO: LSSM
SECTION THREE: OPM1
SECTION FOUR: OPM1
NORTH AMERICA
SWIFT TEST KIT
TRAINING MANUAL
TABLE OF CONTENTS
|
LASER LIGHT SOURCE
|
LASER LIGHT SOURCE
|
OPTICAL POWER METER
|
OPTICAL POWER METER
uclswiftna.com
TEK-4
|
QUICK START GUIDE
|
TECHNICAL GUIDE
|
QUICK START GUIDE
|
REFERENCE & TEST GUIDE

Advertisement

Table of Contents
loading

Summary of Contents for UCL SWIFT TEK-4

  • Page 1 NORTH AMERICA SWIFT TEST KIT TEK-4 TRAINING MANUAL TABLE OF CONTENTS SECTION ONE: LSSM LASER LIGHT SOURCE QUICK START GUIDE SECTION TWO: LSSM LASER LIGHT SOURCE TECHNICAL GUIDE SECTION THREE: OPM1 OPTICAL POWER METER QUICK START GUIDE SECTION FOUR: OPM1 OPTICAL POWER METER REFERENCE &...
  • Page 2 NORTH AMERICA SECTION LSSM LASER LIGHT SOURCE QUICK START GUIDE...
  • Page 3: Quick Start

    Laser Light Source - SM LSSM NORTH AMERICA Low Battery 2kHz Button QUICK START GUIDE Indicator Connector Adapter External Power Change Wavelength Port Button Power Button Wavelength Indicator INTRODUCTION The LSSM dual laser source is a singlemode test laser used for verifying the proper function of fiber optic networks.
  • Page 4: Output Power

    LSSM WARNING Read and understand all of the instructions and safety information in this manual before operating this tool. LASER HAZARD Please note that 1310nm and 1550nm wavelengths are not visible to the human eye. Do not look directly into the output port of the LSSM or directly into any fiber connector that may be live. Since the laser is invisible to the eye, the eye’s natural blink reflex is suppressed.
  • Page 5 LSSM OUTPUT PORT MAINTENANCE The LSSM utilizes a physical fiber connection at the output port. It ensures a steady power level for performing insertion loss tests. Ensure that any test jumpers are inspected and cleaned before plugging into the LSSM unit. If soiled or damaged connectors are inserted, they can cause damage to the LSSM output port and the unit may need to be repaired.
  • Page 6: Maintenance

    LSSM TESTING NOTES Blue connectors (UPC) have a straight ferrule with a domed interface. Green connectors (APC) have an eight-degree angled ferrule with a domed interface. UPC and APC connectors are not compatible. connect UPC and APC connectors together, OR plug NEVER an APC connector into the LSSM unit.
  • Page 7: Specifications

    LSSM PSD1 BATTERY BYPASS SWIFT offers the PSD1 wall plug for users who wish to leave their LSSM turned on for long periods of time. a charger, but rather powers the unit from a wall outlet. This is SPECIFICATIONS DUAL SINGLEMODE LASER SOURCE Wavelength 1310nm &...
  • Page 8 LSSM CERTIFICATIONS This product conforms with health, safety, and environmental protection standards for products sold within the European Economic Area (EEA). This product was tested by an ISO 17025 accredited laboratory and complies with the following CE directives and standards listed below: DIRECTIVES: Electromagnetic Compatibilities (2014/30/EU) STANDARDS: EMC: EN 61326-1:2013 Industrial;...
  • Page 9 NORTH AMERICA SECTION LSSM LASER LIGHT SOURCE TECHNICAL GUIDE...
  • Page 10 The LSSM dual laser source provides stabilized optical power levels for accurate loss measurements on singlemode fiber systems. Technicians can utilize each of the wavelengths included in this light source to reference and test with UCL Swift’s optical power meters and gather measurements to meet international standards.
  • Page 11 LSSM SPECIFICATIONS DUAL SINGLEMODE LASER SOURCE Wavelength 1310nm & 1550nm -5.0dBm Output Power ±0.05dB (1 hour) Output Stability ±0.03dB long-term (15 min warm-up) Spectral Width 5nm/5nm SC/FC/ST/LC interchangeable Optical Interface Tone Output 2kHz Class 1 (FDA 21 CFR 1040.11) Laser Class Push button toggle/auto-off Power Battery...
  • Page 12 NORTH AMERICA SECTION THREE OPM1 OPTICAL POWER METER QUICK START GUIDE...
  • Page 13 OPM1 Optical Power Meter NORTH AMERICA Save Button USB Button QUICK START GUIDE 2kHz Tone Button Indicator Low Battery Indicator Connector Adapter Power Button dB/dBm Measurement Button Mode Indicator LCD Screen Wavelength FEATURES Button The OPM1 comes with a 2.5mm universal adapter. Additional adapters CONNECTOR ADAPTER are available from SWIFT.
  • Page 14: Important Safety Information

    OPM1 Hold the button to switch the OPM1 between the 850, 1300, 1310, 1490, 1550, 1611, and 1625nm wavelengths. Press the button once to WAVELENGTH BUTTON immediately display the current wavelength. The selected wavelength will briefly appear on-screen every 8 seconds. Press the button to toggle between dB and dBm modes.
  • Page 15 OPM1 FUNCTION TIPS AUDIBLE ALERTS The OPM1 emits an audible beep each time a major function is used. To disable most beeps, ensure that the unit is OFF. Press and hold the Save button, and turn the unit ON while holding the Save button. Perform the same procedure to turn the audible beeps back on.
  • Page 16: Data Streaming

    The connector adapter interface should be kept covered and protected from contamination. Care must be taken to avoid objects that may damage the glass surface of the detector mount. If scratches or breaks occur on the surface, please contact UCL Swift NA for proper service. CALIBRATION All SWIFT brand products include a 2-year warranty.
  • Page 17 OPM1 SPECIFICATIONS OPTICAL POWER METER -02: InGaAs/-04: Filtered InGaAs Detector Type -02: +6 to -70dBm/-04: +23 to -45dBm Measurement Range Wavelength Range 850nm to 1650nm Selectable Wavelengths 850/1300/1310/1490/1550/1611/1625nm Resolution 0.01dB ±0.25dB (23ºC +/- 2ºC at 0dBm) Absolute Accuracy Optical Interface Universal 2.5mm (additional adapters available) Display Tone ID...
  • Page 18 OPM1 CERTIFICATIONS This product conforms with health, safety, and environmental protection standards for products sold within the European Economic Area (EEA). This product was tested by an ISO 17025 accredited laboratory and complies with the following CE directives and standards listed below: DIRECTIVES: Electromagnetic Compatibilities (2014/30/EU) STANDARDS: EMC: EN 61326-1:2013 Industrial;...
  • Page 19 NORTH AMERICA SECTION FOUR OPM1 OPTICAL POWER METER REFERENCE & TEST GUIDE...
  • Page 20 OPM1 Optical Power Meter NORTH AMERICA REFERENCE & TEST GUIDE INTRODUCTION Performing a test for Insertion Loss (also commonly called dB Loss or Attenuation) on a fiber optic cable requires an Optical Power Meter (OPM) and an Optical Light Source (OLS). This document outlines the specific steps which must be taken with OPM1 optical power meter to perform insertion loss testing on a variety of fiber types and setups.
  • Page 21: Power Meter

    OPM1 Fiber Type Singlemode Fiber Type Singlemode EXAMPLE 1: SINGLEMODE FIBER, POINT-TO-POINT, 1 JUMPER Singlemode Fiber Type Test Jumper Setup Single Test Jumper Setup Single Connectors Used Simplex jumper SC/LC OPM Used RP 460 Test Jumper Setup OPM Used RP 460 OPM1 OPM Used OLS Used...
  • Page 22: Setting Reference

    OPM1 The connectors on the Test Jumper should be cleaned to appropriate standards. Use an inspection scope to verify fiber cleanliness. Plug the connectors on the Test Jumper into the RP 460 and DLS 355. The connectors on the Test Jumper should be cleaned to appropriate standards. Use an inspection The connectors on the Test Jumper should be cleaned to appropriate standards.
  • Page 23 OPM1 Fiber Type Singlemode Fiber Type Singlemode EXAMPLE 2: SINGLEMODE FIBER, POINT-TO-POINT, 2 JUMPERS Singlemode Fiber Type Test Jumper Setup Double Test Jumper Setup Single Connectors Used (2) Simplex jumpers: (1) SC/LC + (1) LC/LC OPM Used RP 460 Test Jumper Setup OPM Used RP 460 OPM1...
  • Page 24 OPM1 The connectors on the Test Jumper should be cleaned to appropriate standards. Use an inspection scope to verify fiber cleanliness. Plug the connectors on the Test Jumper into the RP 460 and DLS 355. The connectors on the Test Jumper should be cleaned to appropriate standards. Use an inspection The connectors on the Test Jumper should be cleaned to appropriate standards.
  • Page 25 OPM1 Fiber Type Singlemode Fiber Type Singlemode EXAMPLE 3: SINGLEMODE FIBER, PAIRED, LOOPBACK JUMPER Singlemode Fiber Type Test Jumper Setup Loopback Test Jumper Setup Single Connectors Used Loopback OPM Used RP 460 Test Jumper Setup OPM Used RP 460 OPM1 OPM Used OLS Used DLS 355...
  • Page 26 OPM1 The connectors on the Test Jumper should be cleaned to appropriate standards. Use an inspection The connectors on the Test Jumper should be cleaned to appropriate standards. Use an inspection The connectors on the Test Jumper should be cleaned to appropriate standards. Use an inspection REFERENCING SETUP The connectors on the Test Jumper and loopback should be cleaned to appropriate standards.
  • Page 27 OPM1 Fiber Type Multimode Fiber Type Singlemode EXAMPLE 4: MULTIMODE FIBER, POINT-TO-POINT, 1 JUMPER Multimode Fiber Type Test Jumper Setup Single Test Jumper Setup Single Connectors Used (1) Simplex SC/LC OPM Used RP 460 Test Jumper Setup OPM Used RP 460 OPM1 OPM Used OLS Used...
  • Page 28 OPM1 The connectors on the Test Jumper should be cleaned to appropriate standards. Use an inspection The connectors on the Test Jumper should be cleaned to appropriate standards. Use an inspection The connectors on the Test Jumper and loopback should be cleaned to appropriate standards. Use The connectors on the Test Jumper should be cleaned to appropriate standards.
  • Page 29 OPM1 Fiber Type Multimode Fiber Type Singlemode EXAMPLE 5: MULTIMODE FIBER, PAIRED, LOOPBACK JUMPER Multimode Fiber Type Test Jumper Setup Loopback Test Jumper Setup Single Connectors Used Loopback OPM Used RP 460 Test Jumper Setup OPM Used RP 460 OPM1 OPM Used OLS Used DLS 350...
  • Page 30 OPM1 The connectors on the Test Jumper and loopback should be cleaned to appropriate standards. Use The connectors on the Test Jumper should be cleaned to appropriate standards. Use an inspection The connectors on the Test Jumper and loopback should be cleaned to appropriate standards. Use The connectors on the Test Jumper should be cleaned to appropriate standards.

Table of Contents