1. Using the narrow slotted screwdriver or similar, remove
the screw cover from the front panel.
How to remove the screw cover
a. Press the top of the screw cover with the flat-tipped
screwdriver (or nail, etc).
b. Insert the flat-tipped screwdriver (or nail, etc) into
the lower clearance, and pull and lift it toward you
for removal.
2. Remove two screws from the front panel.
3. Open the open panel, and remove the two air filters.
4. Remove one inner screw.
Note: During reassembly, don't tighten the screw
strongly, or it will become idle.

DISASSEMBLING PROCEDURE

Screw cover
5. Remove the fastening screw which retains the cable,
and remove the cord.
Note: During reassembly, install the holder after
installing the front panel. This will make it
easier to assemble the front panel.
6. After closing the open panel, open the horizontal
adjustment louver and pull out the bottom of the front
panel toward you.
Lifting the front panel, strongly pull the top toward you.
Making the front panel parallel to the main body,
strongly pull it toward you for removal.
To install the front panel, place the bottom of the front
panel under the open horizontal adjustment louver,
and press in the front panel, parallel to the cabinet.
When pressing it in, take care to prevent the top of the
blow-out port of the drain pan from being caught by the
front panel.
7. Remove the unit-to-unit wiring from the terminal board.
(Loosen the screw with the screwdriver, and pull out
the wiring.)
8. Remove one fastening screw from the control box
cover.