8
The carrier hangs on the fixings and so there must be a minimum of 10mm
top clearance above the carrier to enable it to be located over the screw
heads before it is lowered onto the M4 fixings.
(
43.4
)
(
36
)
Figure 4 .4 - Surface-mount hole positions and dimensions
The four M4 fixing screws should be screwed into the (panel) surface leaving
approximately 5–6mm of thread visible between the screw head and panel. Mount
the carrier over the heads of the screw fixings and then lower it into position.
Four holes in the carrier circuit board, indicated as 'A' in Figure 4.3, provide screwdriver
access to the four fixings screw once the carrier is mounted. These holes are always
visible and do not require the removal of any modules.
Tighten the screws to the recommended torque of 0.5Nm.
On completing the mounting procedure, confirm:
that the assembly has not suffered any structural damage,
the carrier has not been distorted,
all mounting screws are tightened as recommended.
Removal is the reverse of the fitting procedure.