    To Delete A Zone Timer QZW-100 QZB-100 To Add A Second Zone Timer Battery Power Indicator Frequently Asked Questions Please read this manual carefully and keep it for future reference. For more details, contact ActronAir on 1800 119 229. Specifications...
  • Page 3: Zone Control/Remote Sensor Installation

    Zone Control / Remote Sensor Installation Power Supply Options (applicable for both zone controller and remote sensor) AAA Battery Supply Location • ENSURE that the zone device (zone controller or remote sensor) distance from wall controller (master or secondary) is within the recommended RF range of 30m.
  • Page 4 Run a green Cat5E cable through a 25mm diameter hole in the wall. 43mm Plug in RJ45 connector and secure the controller in the control bracket. 43mm Available ActronAir Cat5E green cable: P.N. 4070-027 7 metres P.N. 4070-031 20 metres Zone controller or...
  • Page 5 Cable Installation Maximum Cable Length 8 Zone Module Zone Power Cable ITEM (see figure on previous page) DESCRIPTION MAXIMUM CABLE LENGTH Cat5E Spec Cables with RJ45 Connectors - Grey Colour 1 to 2 and 1 to 3 8-zone module to 3-way cable joiner (P.N. 4070-012) 0.175m 1 to 9 8-zone module to zone controller...
  • Page 6: Pairing A Zone Controller

    Pairing a Zone Controller Welcome! On master controller, go to ‘MENU’ > Settings > System Settings> Press and hold the ‘Pair’ button until 3 green light flashes Device is not connected to the AC Zone Settings, then select which zone to set up. (on the button).
  • Page 7: To Unpair A Zone Controller

    To Unpair a Zone Controller Zone Control Identification Zone name Touch on the right side of the zone control. Light sensor Battery Level Damper position Dining Dining Dining Dining 24.0 24.0 Zone temp 22.0 22.0 Zone Set Temp Indoor fan speed Air-condition Mode COOL COOL...
  • Page 8: System Setting

    System Settings Zone Settings For more information Dining MENU EXIT SYSTEM AC MODE Dining MENU BACK BACK EXIT BACK ZONE BACK TIMER 24.0 24.0 SYSTEM SETTINGS AC MODE AUTO COOL SYSTEM SETTINGS TIMER ADD A TIMER on timer setting COMFORT RANGE COMFORT RANGE ZONE SETTINGS 18.0 - 23.0...
  • Page 9: To View Zone Status

    To View Zone Status To Add A Zone Timer Set Temperature: Zone set point. SET TIMER Dining MENU STATUS BACK ZONE BACK TIMER BACK ADD TIMER BACK EXIT BACK 24.0 HOURS SYSTEM SETTINGS Set / Room: 22.0 / 23.0 TIMER TURN ZONE ON ADD A TIMER Room Temperature:...
  • Page 10: To Edit A Zone Timer

    To Edit A Zone Timer Battery Power Indicator Battery level of zone controller can also be viewed on master wall controller, MENU > SETTINGS > ZONE SETTINGS. BACK TIMER BACK TIMER BACK EDIT TIMER BACK SET TIMER 02 00 01 00 TURN ZONE ON HOURS ZONE ON...
  • Page 11: Frequently Asked Questions

    Frequently Asked Questions (FAQ) 1. Q: Do I need a WiFi signal or internet connection to install the QUE system? 7. Q: What power source options are available for the Zone Controller and Remote Sensor? A. No. You can install and use a QUE system without a WiFi signal or internet connection. Because the zone devices use inbuilt RF A.
  • Page 12: Specifications

    Remote Sensor (QSB-10 / QSW-10) Electrical Power supply option DC Power or Battery DC Power or Battery DC Power ~12VDC ±5% ~12VDC ±5% Cable specification ActronAir Cable ActronAir Cable Cable length 20m max 20m max Battery 4 - AAA 2 - AAA Screen Display...