light conditions: up to 800 meters
medium conditions: up to 350 meters
tough conditions: up to 60 meters
MAINTENANCE
Before any work on the machine
itself, remove battery from
Note: To ensure long and reliable service, carry out
the following maintenance regularly.
Regularly check for obvious defects such as loose
fixings, and worn or damaged components.
Check that covers and guards are undamaged and
correctly fitted. Carry out necessary maintenance or
repairs before using.
If the trimmer should happen to fail despite the care
taken in manufacture and testing, repair should be
carried out by an authorized customer service agent

BLADE MAINTENANCE

Before any work on the machine
itself, remove battery from
To remove the worn blade push in direction of the
arrow until it snaps off the pivot.(Fig.16)
Clean the pivot of any residual plastic/debris with a
sharp knife.
To refit the new blade place the eyelet over the pivot
and pull outwards until it snaps into place.
machine.
machine.
AFTER TRIMMING / STORAGE
After Trimming/Storage
Stop and remove battery from
product. Ensure battery is
removed before storage.
Clean the exterior of the machine thoroughly using a
soft brush and cloth. Do not use water, solvents or
polishes. Remove all grass and debris, especially
from the ventilation slots .
Turn the machine on its side and clean the cutting
guard inside. If grass cuttings are compacted,
remove with a wooden or plastic implement.
Battery should be stored between 0 – 45° C;
incorrect storage could result in the battery being
damaged.
Charge the battery 1 hour before storing.
During storage, charge the battery at least once
every three months to protect it from damage.

TECHNICAL DATA

Voltage V
-1
No load speed min
Max. cutting circle mm
autonomy
Battery
Weight kg
Charger
Mains voltage V
Mains frequency Hz
Noise/Vibration Information
Noise emission values measured according to
relevant standard :
Acoustic pressure level LpA
78 dB(A)
Acoustic power level LwA
88.3 dB(A)
Guaranteed sound power
The sound power pressure may
exceed 85 dB(A), in this case
individual hearing protection
Weighted root mean square acceleration according
to relevant standard. :
5,8 m/s²
K=2.3 m/s²
18
8000
260
+/-30 min
1.3 Ah Li-Ion
1.9
100-240
50-60
21Vdc 1500mA
K = 3 dB(A)
K = 3.04 dB(A)
LwA 91 dB(A)
ATTENTION !
must be worn.