The second terminal emulation mode is Manual
Update Mode which allows the user to manually
update the provisioning option screens. This mode
supports efficient print screen and log file utilities for
storage of key provisioning parameters, alarm or
performance history and current system status. "3
SPACES TO UPDATE" appears at the top of each
screen. By pressing the space bar 3 times the screen
will be refreshed and will reflect the most current
circuit conditions and provisioning options.
CIRCUIT ID:
LOCATION
ALARM
--------------------------------------------------------------------------------
H2TU-C
RED(LOS/LOF) 01/01/00
(DSX-1)
YELLOW(RAI)
BLUE(AIS)
H2TU-R
RED(LOS/LOF)
(DS1)
YELLOW(RAI)
BLUE(AIS)
--------------------------------------------------------------------------------
1. T1 Alarm
61222024L6-5A
Press ESC to return to previous
T1 Alarm History
FIRST
00:00:04
01/01/00
00:00:31
2. HDSL2 Span
Selection:

Figure 17. Alarm History Screen

61222024L6-5, Issue 1
The Alarm History Screen, illustrated in Figure 17,
provides the user with a detailed alarm history and
events log for the HDSL2 and T1 spans. This screen
includes a time, date, first/last occurrence and count
for each type of HDSL2 or T1 alarm.
01/01/00 00:41:34
smenuen
LAST
CURRENT
01/01/00
00:00:04
Alarm
OK
OK
OK
OK
01/01/00
00:00:31
Alarm
C. Clear T1 Alarm
COUNT
001
000
000
000
000
001