ZKTeco ZK-D4330 User Manual

ZKTeco ZK-D4330 User Manual

Walk through metal detector
Hide thumbs Also See for ZK-D4330:

Advertisement

Quick Links

ZK-D4330 (TP Version)
User Manual
Walk Through Metal Detector
ZK-D4330 (TP Version)
Date: June 2021
Doc Version: 1.0
English
Thank you for choosing our product. Please read the instructions
carefully before operation. Follow these instructions to ensure that the
product is functioning properly. The images shown in this manual are for
illustrative purposes only.
For further details, please visit our Company's website
www.zkteco.com.
User Manual
Contents 1

Advertisement

Table of Contents
loading

Summary of Contents for ZKTeco ZK-D4330

  • Page 1 ZK-D4330 (TP Version) User Manual User Manual Walk Through Metal Detector ZK-D4330 (TP Version) Date: June 2021 Doc Version: 1.0 English Thank you for choosing our product. Please read the instructions carefully before operation. Follow these instructions to ensure that the product is functioning properly.
  • Page 2 The copyright in all the documents, drawings, etc. in relation to the ZKTeco supplied equipment vests in and is the property of ZKTeco. The contents hereof should not be used or shared by the receiver with any third party without express written permission of ZKTeco.
  • Page 3 ZKTeco has been advised of the possibility of such damages. This manual and the information contained therein may include technical, other inaccuracies or typographical errors.
  • Page 4 User Manual About the Company ZKTeco is one of the world’s largest manufacturer of RFID and Biometric (Fingerprint, Facial, Finger-vein) readers. Product offerings include Access Control readers and panels, Near & Far- range Facial Recognition Cameras, Elevator/floor access controllers, Turnstiles, License Plate Recognition (LPR) gate controllers and Consumer products including battery-operated fingerprint and face-reader Door Locks.
  • Page 5: Table Of Contents

    4 PERFORMANCE AND TECHNICAL FEATURES ............ 18 5 CONTROL PANEL ....................19 6 REMOTE CONTROL DESCRIPTION ..............20 7 DETECTION ZONES ..................... 21 7.1 ADJUSTMENT OF DETECTION ZONE’S SENSITIVITY............ 21 8 OPERATIONAL PROCEDURE ................22 P a g e Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 6 8.9 SCENARIO .......................... 36 8.10 LOG QUERY ........................37 8.11 SYSTEM SETTINGS ......................38 8.12 DEFAULT PARAMETERS ....................44 TROUBLESHOOTING ..................... 45 PACKING LIST......................46 WARRANTY CARD ....................47 P a g e Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 7: Overview

    Overview Introduction ZK-D4330 (TP Version) Walk Through Metal Detector, also known as Security Door, is a fixed detection device used primarily for inspecting the metal items concealed on the body. When a person passes through the device carrying metal object(s) larger than the preset size, the device will immediately generate alarms, and display the alarm location as well.
  • Page 8: Components

    ZK-D4330 (TP Version) User Manual Components Transparent Rainproof Alarm Indicator Post Canopy (Optional) Infrared Sensors Front Beam Waterproof Foot Cover Rear Beam Power Interface, Reserved Linkage Host Interface & Power Button P a g e Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 9: Product Specifications

    Operating Temperature -20°C to 50°C External 2220(H) x 930(W) x 760(D) mm Dimensions Channel 2010(H) x 760(W) x 760(D) mm Package 2300(H) x 335(W) x 800(D) mm Weight 70 kg P a g e Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 10: Installation

    If the detector alarms when someone passes through indicates that there is/are some metal object(s) concealed in his/her body. The security guard can use a hand-held metal detector to precisely detect the metals position according to the alarm zones. P a g e Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 11: Installation Setup Requirements

    4 or more > 50 cm NOTE: The detectors must operate at a different frequency to avoid interference. The distance varies according to the actual working environment. P a g e | 10 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 12: Installation Steps

    Step 2: Connect the rear beam with the left and right door panels with bolts, as shown in the figure 3-2 below (note that the bolts are not tightened at this time). P a g e | 11 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 13 ZK-D4330 (TP Version) User Manual Figure 3-2 Step 3: Open the beam cover, as shown in the figure3-3 below. Figure 3-3 P a g e | 12 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 14 Step 4: Connect the front beam with the left and right door panels with bolts and tighten 8 bolts, as shown in the figure 3-5 below. Figure 3-5 P a g e | 13 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 15 3-6 below. Figure 3-6 Step 6: Pass the host signal line through the opening of the front beam, as shown in the figure 3-7 below. Figure 3-7 P a g e | 14 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 16 Step 8: Insert and tighten the left and right signal wire plugs, as shown in the figure 3-9 below (pay attention to distinguish the left and right signal wires). Figure 3-9 P a g e | 15 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 17 Step 9: Cover the beam cover, as shown in the figure 3-10 below. Figure 3-10 The installation skills are shown in the figure 3-11 below: Figure 3-11 P a g e | 16 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 18 Step 10: Lift and move the security gate to the designated working position, connect the side power cord, and press the power switch to enter the working state, as shown in the figure 3-12 below. Figure 3-12 P a g e | 17 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 19: Performance And Technical Features

    Micro Processor Technology: The Microprocessor Control Unit generates the electromagnetic waves for scanning. The scanning rate can be precisely controlled. Adjustable Sensitivity: ZK-D4330 detection zones have 1 to 500 sensitivity levels. You can preset the metal size for excluding items like coins, keys, jewelry, buckle, etc.
  • Page 20: Control Panel

    Turn on the device or press and hold for 3 Power Button seconds on the standby interface to turn off the device. Light Infrared remote signal receive terminal. P a g e | 19 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 21: Remote Control Description

    Selects a menu item or increases a value. DOWN / RIGHT Selects a menu item or decreases a value. ENTER Menu key, confirmation key and adjustment value. P a g e | 20 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 22: Detection Zones

    You can exclude the small portable metal objects from being scanned such as rings, key, belt buckle, shoes, and so on, by following the steps given below : P a g e | 21 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 23: Operational Procedure

    The standby interface displays the following content: Device ID Number, Date and Time, Working Channel, Entry Count, Exit Count, Alarm Count, In-Out Difference, Alarm Rate, Total number and detection signal strength, etc. P a g e | 22 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 24: Main Menu

    Operation: Press the [OK] button to enter the verification password input interface, then press the [OK] button to set the value, press the [▲]/ [▼] button to switch, select "Confirm" and then press the [OK] button to save and exit. P a g e | 23 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 25 Password, Screen System Sleep, Date / Time, Language, Saved Records, Reset, Detect Mode, Relay Mode, and Custom ID etc. P a g e | 24 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 26: Sensitivity Adjustment

    500, the default value is 475. Zone Sensitivity  Select Zone Sensitivity on the Sensitivity interface and press OK to get into its setting interface, as shown in the following: P a g e | 25 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 27: Zone Mode

    In the zone mode, you can select the number of independent zone according to the operational needs of the device. Select Zone on the Main Menu interface, and press OK to select the particular zone settings, as shown in the following: P a g e | 26 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 28 Operation: Press the [OK] button to enter the zone setting interface, then press the [▲]/ [▼] button to select, press [OK] button to save and exit. Remark: Different independent zones, the Zone Sensitivity interface is as follows: P a g e | 27 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 29: Channel Settings

    Select Manual Setting on the Channel interface and press OK to get into its setting interface. The channel range is from 1 to 100, the default value is 35. P a g e | 28 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 30 Operation: Press the [OK] button to enter the auto setting interface and the device will execute the automatic setting. When it prompts "Settings Completed", it will complete the automatic setting of the frequency band and jump to the main menu. P a g e | 29 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 31: Alarm Settings

    [OK] button to save and exit to the upper menu after finishing, directly press [⏎] button to exit to the upper menu without saving the current value. P a g e | 30 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 32 Ring Tone  Select Ring Tone on the Alarm setting interface, and press OK to enter the alarm alarm ring setting interface, as shown in the following: P a g e | 31 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 33 In the Single Zone alarm mode, only the zone with the strongest metal content is detected and the alarm lamp lights up. Facilitate the security Single Zone personnel to precisely focus on the area for detection. P a g e | 32 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 34: Auto Testing

    Auto Testing Select Auto Testing on the Main Menu interface, and press OK to enter this option where the system self-checks its functions. As shown in the following: P a g e | 33 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 35 Operation: Press the [OK] button to enter the partition test, then press [⏎] button to exit to the upper menu. LED Test  Select LED Test on the Alarm setting interface, and press OK to enter the lighting test. The test example is shown below. P a g e | 34 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 36 Operation: Press the [OK] button to enter the voice test. Then continue to press the [OK] button to play 5 voice content one by one, press the [⏎] button to exit and return to the previous menu. P a g e | 35 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 37: Security Level

    Operation: Press the [OK] button to enter the application scenario setting, then press the [▲]/ [▼] button to select the scenarios, press [OK] button to save and exit. P a g e | 36 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 38: Log Query

    〈 return icon to save and exit. 8.10 Log Query Select Log Query on the Main Menu interface, and press OK to enter the log query interface, as shown in the following: P a g e | 37 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 39: System Settings

    Password  Select Password on the System setting interface, and press OK to enter the password setting interface, as shown in the following: P a g e | 38 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 40 Operation: Press the [OK] button to enter the screen hibernation setting, then press the [▲]/ [▼] button to select. Press [OK] button to save and exit to the upper menu after finishing. P a g e | 39 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 41 Select "Confirm" in the pop-up confirmation window and press the [OK] button to confirm, the device will automatically restart, and the set language interface will be displayed after completion. P a g e | 40 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 42 Press [OK] button to save and exit to the upper menu. Reset  Select Reset on the System setting interface, and press OK to enter the restore factory settings interface, as shown in the following: P a g e | 41 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 43 Operation: Press the [OK] button to enter the detect mode setting interface, then press the [▲]/ [▼] button to select, press [OK] button to save and exit. P a g e | 42 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 44 [OK] button to save and exit. Custom ID  Select Custom ID on the System setting interface, and press OK to enter the custom ID setting interface, as shown in the following: P a g e | 43 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 45: Default Parameters

    1- 33 Zone Sensitivity Overall Sensitivity Screen Hibernation 120s Alarm Bell Ring Tone 1 Security Level High Detection Mode Infrared Detection Mode Device ID 123456 Language English P a g e | 44 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 46: Troubleshooting

    If not, change the installation location. If the false alarm is not caused by environmental interference, then reduce the sensitivity level of all zones. Change the frequency. P a g e | 45 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 47: Packing List

    Host 1 pc Adjustable Metal Bracket 1 set Power Adapter 1 set Remote Control 1 pc Bolt 10 pcs Torx Screwdriver 1 pc Allen Screw 4 pcs P a g e | 46 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 48: Warranty Card

    This card will not be issued again if it is lost. Model Number Date of Acquisition User Post Code Address User’s Phone Number P a g e | 47 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 49 ZK-D4330 (TP Version) User Manual Date of Maintenance Record of Maintenance Technician P a g e | 48 Copyright©2021 ZKTECO CO., LTD. All rights reserved.
  • Page 50 ZKTeco Industrial Park, No. 32, Industrial Road, Tangxia Town, Dongguan, China. Phone : +86 769 - 82109991 : +86 755 - 89602394 www.zkteco.com Copyright@2021 ZKTECO CO., LTD. All rights reserved.

Table of Contents