Thank you for choosing our product. Please read the instructions
carefully before operation. Follow these instructions to ensure that the
product is functioning properly. The images shown in this manual are for
illustrative purposes only.
For further details, please visit our Company's website
www.zkteco.in
User Manual
Contents 1

Advertisement

Table of Contents
loading

Summary of Contents for ZKTeco ZK-D1065L

  • Page 1 ZK-D1065L User Manual User Manual Walk Through Metal Detector ZK-D1065L Date: July 2021 Doc Version: 1.0 English Thank you for choosing our product. Please read the instructions carefully before operation. Follow these instructions to ensure that the product is functioning properly. The images shown in this manual are for illustrative purposes only.
  • Page 2 User Manual Without the prior written consent of ZKTeco, no portion of this manual can be copied or forwarded in any way or form. All parts of this manual belong to ZKTeco and its subsidiaries (hereinafter the "Company" or "ZKTeco").
  • Page 3 ZKTeco in no event shall be liable to the user or any third party for any incidental, consequential, indirect, special, or exemplary damages, including, without...
  • Page 4 ZK-D1065L User Manual ZKTeco shall in no way be responsible (i) in case the machine/unit/equipment malfunctions due to any non-compliance of the instructions contained in this manual (ii) in case of operation of the machine/unit/equipment beyond the rate limits (iii) in case of operation of the machine and equipment in conditions di erent from the prescribed conditions of the manual.
  • Page 5 ZK-D1065L User Manual About the Company ZKTeco is one of the world’s largest manufacturer of RFID and Biometric (Fingerprint, Facial, Finger-vein) readers. Product o erings include Access Control readers and panels, Near & Far-range Facial Recognition Cameras, Elevator/ oor access controllers, Turnstiles, License Plate Recognition (LPR) gate controllers and Consumer products including battery-operated ngerprint and face-reader Door Locks.
  • Page 6: Table Of Contents

    ZK-D1065L User Manual Table of Contents OVERVIEW ....................... 7 INTRODUCTION ....................7 APPEARANCE ..................... 7 COMPONENTS ....................8 PRODUCT SPECIFICATIONS ................9 DIMENSIONS ...................... 9 TECHNICAL SPECIFICATIONS .................10 INSTALLATION SETUP ................... 11 SAFETY PRECAUTIONS ...................11 INSTRUCTIONS TO PEDESTRIANS ..............11 INSTALLATION SITE ..................12 3.3.1...
  • Page 7 ZK-D1065L User Manual ADJUSTMENT OF DETECTION ZONE’S SENSITIVITY ........18 OPERATIONAL PROCEDURE................19 SENSITIVITY ADJUSTMENT ................20 OPERATING FREQUENCY ................20 BUZZER SETTINGS ...................20 ALARM TIME .....................21 DATE AND TIME ....................21 SENSITIVITY RANGE ..................22 APPLICATION AREA ..................22 DATA STORAGE ....................22 LOGIN PASSWORD ...................23 7.10...
  • Page 8: Overview

    User Manual Overview Introduction ZK-D1065L metal-detector is a walk-through metal-detector that is used for security screening at access points in the prisons, courthouses, and airports. Metal-detectors are highly sensitive to magnetic metals and have a high detection capability, with less ability to detect non-magnetic metals. They are used to detect the concealed metal weapons on a person’s body.
  • Page 9: Components

    ZK-D1065L User Manual Components Beam LED Alarm Zones Built-in Probe Infrared Sensors Waterproof Foot Cover Power-line Interface P a g e...
  • Page 10: Product Specifications

    ZK-D1065L User Manual Product Speci cations Dimensions P a g e...
  • Page 11: Technical Specifications

    ZK-D1065L User Manual Technical Speci cations Feature Speci cations Power 100V to 240V Operating Temperature -20°C to 55°C Operating Frequency 5.7KHz to 9.6KHz External 2236(H)x827(W)x380(D)mm Dimensions Channel 1990(H)x690(W)x300(D)mm Weight 33kg P a g e | 10...
  • Page 12: Installation Setup

    ZK-D1065L User Manual Installation Setup Safety Precautions Install the detector in a stable and smooth area. Make sure that the detector is installed rmly in the selected area. It can be used for both indoor and outdoor purposes. If used outdoor, cover it with a canopy to protect against rain.
  • Page 13: Installation Site

    ZK-D1065L User Manual Before passing through the metal detector, the pedestrians must remove all the carried metal objects (such as keys, mobile phone, watch, coins, etc.), and place it on the security chute or a table, and pick it up after the security check.
  • Page 14: Parallel Installation

    ZK-D1065L User Manual The sources of electromagnetic radiation and electromagnetic interference are given below: Electrical Control Box, Radiofrequency equipment, Interphone, High Power Motor, Power Transformer, Ac Power Lines, Thyristor Control Circuit (High Power Switching Power Supply, Inverter Welder), Engine, Motor, etc.
  • Page 15 ZK-D1065L User Manual Right Door Panel Left Door Panel Open the Control unit and Door panel package. Install the control unit and the door panels as shown in the above diagram. Connect the door panels to the control unit with bolts and nuts and tighten the screws.
  • Page 16: Performance And Technical Features

    ZK-D1065L User Manual Performance and Technical Features Accurate Positioning: There are 6 overlapping detection zones with bilateral transmit and receive technology. The detection zones can accurately detect the objects with an intuitive display of the target location. Micro Processor Technology: The Microprocessor Control Unit generates the electromagnetic waves for scanning and the scanning rate can be precisely controlled.
  • Page 17: Control Panel

    ZK-D1065L User Manual Control Panel The components of the Control Panel are given below: LCD: Displays the Pass count, Alarm count, Password settings, and other information. ESC: Press to discard the settings and exit the menu. : Adjustment (decrement) key to decrease the parameter values.
  • Page 18: Detection Zones

    ZK-D1065L User Manual Detection Zones The ZK-D1065L detector can detect a wide range of threat objects/weapons composed of magnetic, non-magnetic metals and alloys. Chassis panel: The screen shows the number of people passing the detector and the number of alarms.
  • Page 19: Adjustment Of Detection Zone's Sensitivity

    ZK-D1065L User Manual Infrared Sensor After connecting the power supply, the metal detector starts to work. When there is no person or object passes through the detector, the infrared sensors can e ectively stop alarming to avoid false alarms. It also helps to maintain an accurate count of pedestrians and alarms.
  • Page 20: Operational Procedure

    ZK-D1065L User Manual Operational Procedure Connect the power supply to the detector. After 2 seconds of initialization, you can perform the following operations. Press the OK button on the Control panel to open the main menu. MENU Sensitivity Channel Buzzer Alarm Time Date &...
  • Page 21: Sensitivity Adjustment

    ZK-D1065L User Manual Sensitivity Adjustment On the main menu, select Sensitivity and press OK to set the sensitivity level of each detection zone. Press “ ” and “ ” to select the detection zone and then press OK to con rm. Then press “ ” and “ ” to change the sensitivity values. The larger the sensitivity value, the higher the sensitivity.
  • Page 22: Alarm Time

    ZK-D1065L User Manual Buzzer Alarm Time In the main menu, select Alarm Time and then press OK to con rm. The default alarm time is 1 second. Press “ ” and “ ” to select the alarm time as per your requirements and press OK to save the settings.
  • Page 23: Sensitivity Range

    ZK-D1065L User Manual Sensitivity Range In the main menu, select Sens Range and then press OK to set the intensity of the sensitivity levels. Press “ ” and “ ” to select the sensitivity settings for all the zones. Press OK to save the settings.
  • Page 24: Login Password

    ZK-D1065L User Manual Storage Save Don’t Save Clear Pass (Clear Pedestrian Count) Clear Alarm (Clear Alarm Count) Login Password In the main menu, select Password to con gure the Password. Press “ ” and “ ” to set the password, and press ESC to clear the entered value. Press OK to save the settings.
  • Page 25: Default Parameters

    ZK-D1065L User Manual 7.11 Default Parameters Parameter Default Value Sensitivity Channel Buzzer Alarm Time 1.0 s Application Area Train Station Data Saving Save System Password 100000 P a g e | 24...
  • Page 26: Troubleshooting

    ZK-D1065L User Manual Troubleshooting What to do if the Sensor could not count? Check whether the probe cables are connected rmly with the door panels. Check whether there is any infrared interference beside the device, such as infrared surveillance system, infrared remote control, outdoor sunlight, etc.
  • Page 27: Packing List

    ZK-D1065L User Manual Packing List The package consists of the following items: Component Quantity Power Adapter 1 set Power Cable 1 set Hexagon Socket Set Screw 8 pcs Inner Hexagon 1 pc User Manual Front Beam 1 pc Rear Beam...
  • Page 28: Warranty Card

    ZK-D1065L User Manual Warranty Card Please keep this card safe and produce the same during maintenance. This card will be invalid without the signature or stamp of the designated dealer. This card will be regarded as invalid if the details are not lled in three guarantees column and the acknowledgment of the receipt.
  • Page 29 ZK-D1065L User Manual Date of Maintenance Record of Maintenance Technician P a g e | 28...
  • Page 30 e- Catalogue B-1, Khata no. 31, Devasandra Industrial Estate White eld Main Road, Beside Phoenix Mall, Mahadevapura, Bengaluru, Karnataka 560048...

Table of Contents