5.7.4 To change the domestic hot water temperature
User reference guide
32
T t
60°C
50°C
40°C
15°C
00:00
T
Storage tank temperature
t
t Time
▪
At 14:00 the DHW schedule is programmed to heat up the tank to 60°C.
▪
At 21:00 the DHW schedule is programmed to heat up the tank to 50°C. This
value is valid until 14:00 the next day.
▪
With the higher set temperature, in the afternoon and evening more hot water is
available.
▪
During the morning, you consume hot water and the storage tank temperature
decreases.
▪
When the tank temperature drops below a preset value (=set temperature –
hysteresis value; example 40°C), the tank is heated up to 50°C.
▪
During the afternoon and evening, you consume hot water again and the DHW
tank temperature decreases again.
▪
When the tank temperature drops below a preset value (=set temperature –
hysteresis value; example 50°C), the tank is heated up to 60°C.
In Reheat only mode, you can use the tank temperature setpoint screen to read
out and adjust the domestic hot water temperature.
1 Go to [5]: Tank.
5
Tank
2 Adjust the domestic hot water temperature.
a
5
50
°C
Tank
a Actual domestic hot water temperature
b Desired domestic hot water temperature
In other modes, you can only view the setpoint screen but not modify it.
When weather-dependent operation is used for the tank, the tank temperature is
determined automatically by the outdoor temperature. For more information, see
"5.9 Weather-dependent
3
4
1
5
2
07:00
14:00
21:00
b
+
–
4
curve" [
42].