Advertisement

Si01-752
REMOVAL
PROCEDURE
S E R V I C E
M A N U A L
2.5/3.5 kW Class
Outdoor Unit
Non-Inverter
Pair Type

Advertisement

loading

Summary of Contents for Daikin RE25JV1

  • Page 1 Si01-752 REMOVAL PROCEDURE S E R V I C E M A N U A L 2.5/3.5 kW Class Outdoor Unit Non-Inverter Pair Type...
  • Page 2 Service Manual Removal Procedure Outdoor Unit Cooling Only RE25JV1 RE35JV1...
  • Page 3: Table Of Contents

    Si01-752 Table of Contents 1. Removal of Outer Panels ................2 2. Removal of Bellmouth ................4 3. Removal of Electrical Components ASSY ..........5 4. Removal of Outdoor Fan / Fan Motor .............6 5. Removal of Sound Blanket..............8 6. Removal of Partition Plate...............9 7.
  • Page 4: Removal Of Outer Panels

    Removal of Outer Panels Si01-752 1. Removal of Outer Panels Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Remove the screw and remove the stop valve cover.
  • Page 5 Si01-752 Removal of Outer Panels Step Procedure Points Remove the screw at The left side plate and the the rear of the top bellmouth can be removed panel. Once lift the all at once. panel ASSY and then When restoring the panel remove it forward.
  • Page 6: Removal Of Bellmouth

    Removal of Bellmouth Si01-752 2. Removal of Bellmouth Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points The bellmouth is attached with 2 screws Hook A and 4 hooks. Hook B Screw (R1854)
  • Page 7: Removal Of Electrical Components Assy

    Si01-752 Removal of Electrical Components ASSY 3. Removal of Electrical Components ASSY Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points 1. Remove the drip proof plate. Remove the 3 screws of the drip proof plate.
  • Page 8: Removal Of Outdoor Fan / Fan Motor

    Removal of Outdoor Fan / Fan Motor Si01-752 4. Removal of Outdoor Fan / Fan Motor Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Disconnect the 3 Fan motor Black White...
  • Page 9 Si01-752 Removal of Outdoor Fan / Fan Motor Step Procedure Points Remove the fan motor. (R12799) Removal Procedure...
  • Page 10: Removal Of Sound Blanket

    Removal of Sound Blanket Si01-752 5. Removal of Sound Blanket Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points 1. Remove the right side panel. Remove the 3 screws of the right side panel.
  • Page 11: Removal Of Partition Plate

    Si01-752 Removal of Partition Plate 6. Removal of Partition Plate Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Disengage the Compressor lead wire compressor lead wires Wire clip from the wire clip.
  • Page 12: Removal Of Compressor

    Removal of Compressor Si01-752 7. Removal of Compressor Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Before working, make sure that the refrigerant is Warning Lead wires for empty in the circuit.
  • Page 13 Si01-752 Removal of Compressor Step Procedure Points Heat up the brazed part Note: of the discharge side Do not use a metal saw for and disconnect. cutting pipes by all means because the sawdust comes Heat up the brazed part into the circuit.
  • Page 14 Revision History Month / Year Version Revised contents 07 / 2013 Si01-752 First edition...
  • Page 15 Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.