Optical Output; Environment; Table 7: Optical Output Specification; Table 8: Environment Specification - GE Reason RT412 Technical Manual

Optical transceiver
Table of Contents

Advertisement

Chapter 8 – Technical Specification
5

Optical Output

6

Environment

RT412

Table 7: Optical Output specification

Number of Output
Connector
Wavelength
Fiber Type
Emission power
Time Difference between Input and
Outputs (mean)

Table 8: Environment specification

Operating temperature range
As tested per IEC 60068-2-1
As tested per IEC 60068-2-2
Maximum operating altitude
Relative humidity

Table 9: Enclosure Protection IEC 60529

Product safety protection
1
ST
820 nm
Multimode 50/125 µm, 62.5/125 µm,
100/140 µm or 200 µm HCS
- 17.8 dBm (50 / 125 µm)
- 14.0 dBm (62,5 / 125 µm)
- 8.5 dBm (100 / 140 µm)
- 5.7 dBm (200 µm HCS)
73 ns
-40°C ... +55°C (or –40°F to +131°F)
-40°C
+85°C
2000 m (6560 ft)
5 ... 95%, non-condensing
IP20
RT412