Welch Allyn Kreativ User Manual
Welch Allyn Kreativ User Manual

Welch Allyn Kreativ User Manual

Air abrasion system
Hide thumbs Also See for Kreativ:

Advertisement

Quick Links

0D.K
$LU$EUDVLRQ6\VWHP
8VHU·V*XLGH
&RQWHQWV
1. Safety..................................................................... 2
2. Contra-Indications and Indications ...................... 3
3. System Overview ................................................... 3
Filling the Powder Chamber .................................. 4
User Settings ......................................................... 4
5. Using the System................................................... 5
Unit Shutdown........................................................ 5
6. Mach 8 Special Instructions................................... 5
7. Routine Maintenance ............................................. 6
8. Troubleshooting ..................................................... 8
9. Warranty, Returns and Adjustments...................... 9
Returns and Adjustments ...................................... 9
Limited Warranty.................................................... 9
Storage and Shipment ........................................... 9
10. Specifications....................................................... 10
11. Recycling ............................................................. 10
CAUTION: This device must only be purchased by, or
sold to, a licensed dentist. Clinical use of the Mach 7/8
Air Abrasion system for procedures not included or
suggested in this guide is not advised. The Mach 7/8 Air
Abrasion system should only be used by dental
professionals who have practiced on extracted teeth and
are thoroughly familiar with the contents of this manual.
© 2000, Welch Allyn / Kreativ, Inc. All rights reserved. No part of
this manual may be reproduced without written permission
from Welch Allyn / Kreativ, Inc.
Kreativ Menu
Manuals

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Kreativ and is the answer not in the manual?

Questions and answers

Summary of Contents for Welch Allyn Kreativ

  • Page 1: Table Of Contents

    © 2000, Welch Allyn / Kreativ, Inc. All rights reserved. No part of this manual may be reproduced without written permission from Welch Allyn / Kreativ, Inc.
  • Page 2: Safety

    Particle Energy setting of 50-80 PSI. The handpiece must never be directed at soft tissues , Do not substitute non-Welch Allyn / Kreativ materials or even for a brief period of time, because subcutaneous accessories. Use of materials or accessories supplied...
  • Page 3: Contra-Indications And Indications

     &RQWUD,QGL.DWLRQVDQG  6\VWHP2YHUYLHZ ,QGL.DWLRQV The Welch Allyn / Kreativ Mach 7/8 Air Abrasion system is designed to remove tooth structure and other materials to prepare teeth for restoration, and as an adjunct to a high Contra-Indications speed dental handpiece and bur. The system delivers a •...
  • Page 4: System Unpacking, Setup, And Check-Out

    Mach 7/8. If you have a compressor, refer to 3 = Alternating. the compressor User’s Guide for information about use of Welch Allyn / Kreativ compressor air. 3. Press the Particle keys to select a mode for Particle Energy display: 1 = PSI, 2 = kPa.
  • Page 5: Using The System

    Note: Opening the lid of the unit will depressurize provide dual remote functions with separations up to 32 the system and power will turn off. feet. Contact your authorized Welch Allyn / Kreativ representative for these optional accessories. 2. Press the keys to adjust the Particle Energy to provide optimum powder flow.
  • Page 6: Routine Maintenance

     5RXWLQH0DLQWHQDQ.H When a remote control module is plugged into the rear Proper maintenance of the Mach 7/8 system is needed panel of the Mach 8, it functions as a second operatory. to maintain consistent cutting efficiency. Note: There are no user-serviceable parts inside and all servicing (other than explicitly defined in the manual) shall be performed by the manufacturer 1EGL 7IVMIW...
  • Page 7 4. Clean up excess powder to help isolate the leak 5. Replace as necessary. New filters are available area. from your authorized Welch Allyn / Kreativ service 5. If a leak is detected, try re-seating the tube into its representative.
  • Page 8: Troubleshooting

     7URXEOHVKRRWLQJ Refer to the following table before you contact your Welch Allyn / Kreativ service representative. Problem Possible cause Remedy Error Code 35 Footswitch down on Power Up Check switch Error Code E-42-1 (Lo Pdr) Low Powder Add powder...
  • Page 9: Warranty, Returns And Adjustments

    Kreativ approval. Limited Warranty Welch Allyn / Kreativ warrants the equipment to be free from defects in material and workmanship for a period of 12 months from the date of shipment. Damage due to failure of the customer to perform the required user/preventive maintenance is not warranted.
  • Page 10: Recycling

    Welch Allyn / Kreativ. Manufactured by European Regulatory Manager Welch Allyn / Kreativ, Inc. USA Welch Allyn LTD. 7420 Carroll Road Navan, Co. Meath San Diego, CA 92121 Republic of Ireland Ph: 353-46-79060 990154 Rev.

Table of Contents