Download Print this page

Maintenance; Protecting The Environment - Black & Decker KFBCD600 Original Instructions Manual

Advertisement

Problem
Possible cause
Battery pack will not
Charger not plugged
charge.
in.
Surrounding air
temperature too hot or
too cold.
Unit shuts off
Battery pack has
abruptly.
reached its maximum
thermal limit.
Out of charge. (To
maximize the life of
the battery pack it is
designed to shutoff
abruptly when the
charge is depleted

Maintenance

Your BLACK+DECKER tool has been designed to operate
over a long period of time with a minimum of maintenance.
Continuous satisfactory operation depends upon proper tool
care and regular cleaning.
Your charger does not require any maintenance apart from
regular cleaning.
Warning! Before performing any maintenance on the tool,
remove the battery from the tool. Unplug the charger before
cleaning it.
Regularly clean the ventilation slots in your tool and
u
charger using a soft brush or dry cloth.
Regularly clean the motor housing using a damp cloth.
u
Do not use any abrasive or solvent-based cleaner.
Regularly open the chuck and tap it to remove any dust
u
from the interior.

Protecting the environment

Z
Separate collection. Products and batteries
marked with this symbol must not be
disposed of with normal household waste.
Products and batteries contain materials that can be
recovered or recycled reducing the demand for raw
materials.
Please recycle electrical products and batteries according to
local provisions. Further information is available at
www.2helpU.com.
Technical data
Possible solution
Plug charger into a work-
ing outlet.
Move charger and battery
pack to a surrounding air
temperature of above 40
degrees F (45ºC) or below
105 degrees F (+40.5ºC)
Allow battery pack to cool
down.
Place on charger
and allow to charge.
(Original instructions)
Voltage
V
DC
No-load speed
Min
Max. torque
Nm
Chuck capacity
mm
Max Drilling capacity
Steel/wood
mm
Weight
kg
Charger
Input voltage
V
AC
Output voltage
V
DC
Current
mA
Approx. charge time
Hours
ENGLISH
KFBCD600
10.8
-1
0-550rpm
12.5/26
1-10
10/25
0.98
230
10.8
200mA
8
7

Advertisement