Remote Start / Alarm Diagnostics - Fortin RM912 Manual

Security system only remote car starter only security system and remote car starter automatic / manual transmission - 2-way remotes
Table of Contents

Advertisement

a dialectic grease to prevent corrosion.
• Trailer wiring. Corroded or improperly wired trailer wiring may cause the park light signal to bleed
into the brake signal. This will cause the Remote-Starter to shut down as soon as the park lights
are turned on.
• Problems with the Bypass Kit (if installed). If you are able to put the Remote-Starter into Ready
Mode, Idle Mode, or Turbo Mode, but you are unable to Remote-Start the vehicle then the Bypass
Kit may be failing. Several Remote-Start attempts with a failed Bypass Kit may lock your vehicle
for several hours.
• Dash warning lights. The dash should display in exactly the same way when either starting the
vehicle with the key, or with the Remote-Starter. If the dash displays any warning lights (Check
Engine, ABS, or Theft) once Remote-Started then something is wrong. Stop using the Remote-
Starter and have it looked at immediately.
TIP: If your vehicle is experiencing any problems either starting or running with the key have it looked
at by the Remote-Starter's installer fi rst. Having the vehicle worked on by another service centre may
void any warranty and/or guarantees on the Remote-Starter and its Installation. Additionally the original
installation centre may refuse all fees incurred by the latter service centre (if any).

REMOTE START / ALARM DIAGNOSTICS

REMOTE STARTER DIAGNOSTICS
Parking Light fl ashes (before starting) :
3x
Ready mode disabled
4x
Valet mode activated (The LED is on)
5x
Hood open
Parking Light fl ashes (after Shutdown) :
1x
Normal stop (Brake, Park Brake)
3x
Runtime expired or shut down by transmitter
4x
No tachometer signal
5x
Hood open
6x
Over crank threshold (8 seconds)
ALARM DIAGNOSTICS
Parking Light fl ashes (after disarm) :
3x
4x
5x
6x
Page 12 / 12
Door open – zone 3
Shock sensor – zone 4
Hood open – zone 5
Trunk open – zone 6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rem912Ant900Rm942

Table of Contents