Installation Hint For Fmu40/41; Turn Housing - Endress+Hauser Prosonic M FMU40 Brief Operating Instructions

Ultrasonic level measurement
Hide thumbs Also See for Prosonic M FMU40:
Table of Contents

Advertisement

Mounting
2.5

Installation hint for FMU40/41

2.6

Turn housing

After mounting, the housing can be turned 350° in order to simplify access to the display and
the terminal compartment. Proceed as follows to turn the housing to the required position:
• Undo the fixing screws (1)
• Turn the housing (2) in the required direction
• Tighten up the fixing screws (1). Maximum torque 0.5 Nm (0.36 lbf ft).
• Loctite can be used for securing the screw.
12
F12 or T12 housing
Prosonic M FOUNDATION Fieldbus
Caution!
Use only the screw-in
piece to screw in
the Prosonic M
AF 60
max torque
20 Nm (14.75 lbf ft)
L00-FMU4xxxx-17-00-00-en-009
Endress+Hauser

Advertisement

Table of Contents
loading

Table of Contents