INSTALLATION CLEARANCES FOR INBUILT MODELS
IMPORTANT: All distances shown are MINIMUM. ILLUSION Gas Log appliances UGL62NG ,UGL69NG, UGL62LP
and UGL69LP must only be installed with the minimum distances shown below.
Note that these appliances have a DRAFT DIVERTER at the rear of the unit, which exits at the heater mantel and
must not be altered, obstructed or blocked in any way. Modifications or obstructions to the draft diverter or exit may
cause a hazardous situation.
INSTALLATION OPTION 1
500mm MINIMUM
NOTE: ALL FLUE PIPES MUST
BE INSTALLED WITH THE
CRIMPED END FACING UP
100mm ACTIVE FLUE PIPE
THE RECOMMENDED MINIMUM
DISTANCE FROM THE TOP OF
THE APPLIANCE TO THE
UNDERSIDE OF ANY
COMBUSTIBLE TIMBER FRAMING
IS 70mm PROVIDED THAT THE
GAP BETWEEN THE ACTIVE FLUE
PIPE AND ANY COMBUSTIBLE
MATERIAL IS A MINIMUM OF
25mm, OR THE GAP BETWEEN
THE OUTER CASE AND ANY
COMBUSTIBLE MATERIAL IS A
MINIMUM OF 10mm
ESPRIT INBUILT MANUAL 2014
Minumum distance
APPROVED GAS COWL
REFER TO INSTALLATION
INSTRUCTIONS FOR THE
ESPRIT
INBUILT
GAS FIRE
7
TYPICAL ESPRIT INBUILT
CHIMNEY INSTALLATION
FLASHING
SUPPLIED BY INSTALLER
ESPRIT INBUILT