Q u a l i t y & Va l u e I n G a s L o g F i r e s
Main Gas Connection
The connection is made using gas pipes with Rp1/2 ISO 7 threading. Torque: 25Nm
If, alternatively, flanges are used, first screw the pipes on to the flanges and then the
flanges to the valve. Recommended torque for the flange fixing screws: 3Nm.
Connection to the pilot burner
Pipes with Ø 4mm, Ø 6mm or Ø 1/4 can be used. Use a nut and olive of appropriate dimensions.
Tighten the nut to 7 Nm torque.
Electrical Connections
Use the special connectors for connection to the thermopile and to the thermostat.
Make the connections in accordance with the plan below and in accordance with the rules for the appliance. The electrical safety cut
off devices (for example, the flame failure device, limit thermostat and the like) must cut off the power supply to the thermoelectric
circuit of the gas valve.
Caution: After making the connections, check gas tightness.
LABELLING
ILLUSION GAS LOG HEATERS - MODELS EGL62NG, EGL69NG, EGL62LP AND EGL69LP
Model
Gas Type
Gas Consumption Mj/h
Manifold Pressure kPa
Injector Size
Max kW Output
Average Efficiency %
AGA APPROVAL NUMBER- 6286
Electrical components conform to AS 3100
DO NOT
OPERATE THIS APPLIANCE BEFORE READING THE
INSTRUCTION BOOKLET
PLACE ARTICLES ON OR AGAINST THIS
DO NOT
APPLIANCE
DO NOT
STORE CHEMICALS OR FLAMMABLE MATERIALS
OR SPRAY AEROSOLS NEAR THIS APPLIANCE
OPERATE WITH PANELS, COVERS OR GUARDS
DO NOT
REMOVED FROM THIS APPLIANCE
PLEASE NOTE AS PER AGA 103 A PRIMARY SAFETY GUARD IS SUPPLIED
ESPRIT INBUILT MANUAL 2014
EGL62NG
NAT
32
0.95
3.0
7.11
76.9
!
AND MUST BE FITTED WHEN THE HEATER IS OPERATING.
EGL69NG
EGL62LP
NAT
LP
40
29
0.85
1.4
3.8
1.8
8.38
6.3
75.9
78.6
240V 50hz 60 watts
THE GUARD IS FITTED TO THIS
APPLIANCE TO REDUCE THE RISK
OF FIRE OR INJURY FROM BURNS
AND NO PART OF IT SHOULD BE
PERMANENTLY REMOVED.
FOR THE PROTECTION OF YOUNG
CHILDREN OR THE INFIRM,
A SECONDARY GUARD IS REQUIRED.
3
EGL69LP
LP
37
2.25
1.8
Manufactured by
ILLUSION Australia Pty. Ltd.
7.91
145 Sth Gippsland Hwy.
Dandenong Sth.
3175
77.8
Victoria Australia