Q u a l i t y & Va l u e I n G a s L o g F i r e s
NOTE: ALL FLUE PIPES
INCLUDING THE ACTIVE
INNER PIPES MUST BE
INSTALLED WITH THE
CRIMPED END FACING UP
100mm ACTIVE FLUE PIPE
WITH 150mm OUTER CASE
PLASTER OR SIMILAR
WALL FACING WITH TIMBER
OR METAL FRAMING
THE RECOMMENDED MINIMUM
DISTANCE FROM THE TOP OF
THE APPLIANCE TO THE
UNDERSIDE OF ANY
COMBUSTIBLE TIMBER FRAMING
IS 70mm PROVIDED THAT THE
GAP BETWEEN THE ACTIVE FLUE
PIPE AND ANY COMBUSTIBLE
MATERIAL IS A MINIMUM OF
25mm, OR THE GAP BETWEEN
THE OUTER CASE AND ANY
COMBUSTIBLE MATERIAL IS A
MINIMUM OF 10mm
ESPRIT INBUILT MANUAL 2014
INSTALLATION OPTION 3
500mm MINIMUM
100mm ACTIVE FLUE PIPE
ABOVE THE CEILING
RING
ANGLE BRACKET SUPPORT
ANGLE BRACKET SUPPORT
APPROVED GAS COWL
CEILING RING
ESPRIT
INBUILT GAS
FIRE
9
TYPICAL ESPRIT INBUILT
VERTICAL FLUE THROUGH
WALL INSTALLATION
FLASHING
SUPPLIED BY INSTALLER
MINIMUM DISTANCE FROM
ANY OUTER CASE TO ANY
COMBUSTIBLE MATERIAL IS
10mm
REFER TO INSTALLATION
INSTRUCTIONS FOR THE
ESPRIT INBUILT