E2S DL112H Instructions/Service Manual page 4

Alertalight combined metal sounder led beacons

Advertisement

S1 - LED Flash Mode Settings (AC & DC)
The Flash Mode Dip Switch can be changed to set the desired
flash pattern
Flash Mode DIP Switch – Shown with 1-OFF, 2-ON, 3-OFF (0 1 0),
This denotes Flash mode 1Hz. For further flash modes refer to
table:
• All models are approved for use as Audible Signal and Visual Appliance
for use as General Signaling: UL464A & CSA C22.2 No 20 -17, UL1638A
• Type 4 / 4X / 3R / 13, IP66
• -2 °C to +
°C / -13°F to +131°F
• To maintain Ingress Protection, cable entries must be fitted with suitably rated cable glands or stopping plugs
• Units can be mounted using the 2-off 10 x 7mm obround holes in the mounting lugs.
• EOL Monitoring (DC Only): End of Line Devices may be fitted between the +ve & -ve terminals of the PCBA. Please ensure that the device
legs meet the wire size range stated for the connection terminals and are fitted correctly in order to avoid a short. Refer to the compatible
control panel specification for EOL device values and ratings
Model
DL112HDC024
DL112HDC048
DL112HAC11
DL112HAC230
*Nominal Voltage, 1Hz Flash Pattern & Tone 12;
Warnings
Attention: Installation must be carried out by an electrician in compliance with the National Electrical Code, NFPA 70 or CSA 22.1
Canadian Electrical Code, Part I, Safety Standard for Electrical Installations, Section 32. / L'installation doit exclusivement être
réalisée par du personnel qualifié, conformément au code national d'électricité américain, NFPA 70 ou CSA 22.1 Code canadien de
l'électricité, première partie, norme de sécurité relative aux installations électriques, Section 32
Attention: Disconnect from power source before installation or service to prevent electric shock / Débranchez-le de la source
d'alimentation avant l'installation ou l'entretien pour éviter tout choc électrique.
Attention: Do not paint / Ne pas Peinturer
E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH
ON
1 2 3
Nominal* Voltage
Voltage Range
12V dc
10-14Vdc
24V dc
16-30Vdc
48V dc
48-60Vdc
11 V ac
11 V ac ± 10% 0/60Hz
230V ac
230V ac ± 10% 0/60Hz
#
Worst-case input voltage and worst case flash pattern
Switch
Setting
0 0 0
1 0 0
0 1 0
1 1 0
0 0 1
1 0 1
0 1 1
1 1 1
Nominal Operating Current
sales@e2s.com
e2s.com
Flash Mode
Steady on
Blinking
Flashing 1Hz*
Flashing 1. Hz*
Flashing - Double Strike
Flashing - Triple Strike
Flashing 2Hz*
Flashing - Temporal
#
Beacon
Sounder
79. mA
86. mA
60mA
34mA
19mA
D173-00-201-IS Issue 4 19/11/2021
200mA
200mA
120mA
100mA
60mA