5.5 Adaptation to different types of gas
If other types of gas are to be used, the
nozzles must be replaced and the primary
air must be adjusted. The hob has to be
removed in order to replace the nozzles
and adjust the burners.
Removing the hob top
1. Remove the burner caps and then
remove the pan supports by lifting one of
the two horizontal spokes.
2. Remove the knobs.
Installation
3. Remove the flame-spreader crowns.
4. To remove the UR burner (depending on
the model), as well as removing the
burner caps (1), the pan supports (2)
and the flame-spreader crowns (3), also
remove the lower plate (4).
57