  • Page 1 Installation and operating manual AAFs silicon free compressed air filter Please read the following instructions carefully before installing the filter into the service. Trouble-free and safe operating of the filter can only be guaranteed if recommendations and conditions stated in this manual are respected.
  • Page 2 Components Part 1 Pressure drop indicator (optional) 2 Screw 3 Flat seal 4 Head cover 5 Filter head 6 O-ring seal 7 Filter or cyclone element 8 Condensate drain (optional) 9 Filter bowl * Filter housing size 0006 - 0016 does not contain the components: 1, 2, 3, 4, 8.
  • Page 3: Technical Data

    Technical data FILTER PIPE SIZE FILTER FLOW CAPACITY DIMENSIONS [mm] VOLUME WEIGHT HOUSING [inch] ELEMENT [kg] [scfm] AAFs 0006 03528 0,07 0,23 AAFs 0016 05528 0,09 0,24 AAFs 0026 03844 0,22 0,42 AAFs 0036 03844 0,22 0,42 AAFs 0046 06050 0,44 0,72 AAFs 0056...
  • Page 4: Safety Instructions

    Safety instructions The relevant safety at work and accident prevention regulations, plus operating instructions, shall apply for operating the filter. The filter has been constructed in accordance with the generally recognized rules of engineering. It complies with the requirements of directive 2014/68/EU concerning pressure equipment.
  • Page 5: Appropriate Use

    Appropriate use AAFs series filters are designed for high efficient removal of solid particles, water, oil aerosols, hydrocarbons, odour and vapours from compressed air systems. This appliance must be used only for the purpose for which it was specifically designed. All other uses are to be considered incorrect.
  • Page 6: Installation

    Installation Operations should be performed only by qualified personnel. Never operate with installation under pressure. The user is responsible for ensuring that the filter will never operate at a pressure exceeding the nominal values. Eventual over-pressure could be dangerous and hazardous to the operator and the equipment.
  • Page 7 The filter assembly and installation procedures are as follows: Depressurize the system before carrying out the installation work. • Connect the filter head to the compressed air piping and check that the airflow • corresponds to the direction of the arrow positioned on the filter head cap. Lubricate the O-ring and the sealing surfaces of the filter head and cartridge use •...
  • Page 8: Changing The Filter Element

    Changing the filter element...
  • Page 9: Maintenance

    Maintenance Hazard due to a sudden release of pressure! Never remove any parts of the filter for as long as the filter is still pressurized! Depressurize the filter before carrying out any work on the filter. Filter elements are subject to wear. In order to maintain system efficiency, optimal performance and best air quality, these rules of proper maintenance should be followed: If installed, regularly check pressure drop indicator to ensure filter element is not •...
  • Page 10: Warranty Exclusion

    • If the operator damaged the O-ring during the replacement of the filter elements and • do not replace it. OMEGA AIR d.o.o. Ljubljana Cesta Dolomitskega odreda 10 SI-1000 Ljubljana, Slovenia Tel.: +386 (0)1 200 68 00 Fax.: +386 (0)1 200 68 50 E-mail: info@omega-air.si...