Customer Validation Testing
Temperature Test
To insure that the image engine stays within the operating limits of the specification, the following test must be done with the
engine integrated into the designated enclosure.
1. Attach the thermocouple for each engine model as shown below.
2. Configure the scan engine in the desired triggering mode and scan per use case.
Note: Continuous scanning (with no downtime) can produce undesired results.
3. Place the integrated engine into the chamber at the maximum operating temperature (50°C).
4. Record the temperature at various intervals or after the temperature has stabilized.
5. Compare the results with the operating limits.
Note: Testing needs to be performed for each enclosure in which an engine will be used.
Operating Voltage
The operating voltage must be maintained within the engine's specified limits (see
"Operating Voltage" on page
3-1).
Laser Aimer PCB Assembly
Thermocouple
C - 1