Download Print this page

Optex OA-4500S Installation Manual page 2

Advertisement

ADJUSTMENTS
2
Area width adjustment
Width adjustment
Width adjustment
screws (Left)
screws (Right)
1st to 3rd rows
4th and 5th rows
1 2 3
10 11 12
1 2 3
10 11 12
Eliminated
Eliminated
Eliminated Eliminated
Eliminated
Eliminated
Eliminated
Eliminated
Narrow
Narrow
Wide
Wide
NOTE
When adjusting the width adjustment screws, make sure to turn until they click otherwise proper
operation may not be obtained.
cannot be eliminated separately, neither can
1 2 3
3
Dipswitch settings
1,2 : Sensitivity
3,4 : Presence detection timer
Dipswitches
5,6 : Frequency
1 2 3 4 5 6 7
8
9 101112131415
16
7,8 : Row adjustment
9
10
11
3-1.Setting the sensitivity
Recommended sensitivity setting in accordance with the following
mounting height.
L (Low)
: 2.5m(8'2") to 3.5m(11'6")
M (Middle)
: 3.0m(9'10") to 4.0m(13'2")
H (High)
: 3.5m(11'6") to 4.5m(14'9")
S-High(Super high)
: 4.0m(13'2") to 4.5m(14'9")
NOTE
Adjust the sensitivity to suit each installation site.
3-2.Setting the presence detection timer
Presence detection timer can be selected by dipswitch 3 and 4.
NOTE
To enable the presence detection, do not enter the detection area for 10 seconds after setting the timer.
3-3.Setting the frequency
When using more than two sensors close to each other, set a different
frequency for each sensor by dipswitches 5 and 6.
3-4.Setting the row adjustment
Set the rows with dipswitches 7 and 8.
NOTE
When "2rows" is selected, the activation output
is disabled.
3-5.Setting the door cancel function
When dipswitch 9 is "ON" the sensor is less influenced by the door movement, i.e.
caused by wind.
If the sensor does not detect for 10 sec., the 1st row will be disabled when door cancel
function is"ON".
(The 1st row will be enabled again when there is detection at other rows.)
WARNING
With this fuction, 1st row is disabled if there are no ditection for 10sec.
If a person or vehicle enter the first row without any detection in other rows
Risk of getting caught.
(e.g. enter from the other side), it might cause an accident.
3-6.Setting the ON delay 2 sec.
To avoid unnecessary openings due to passing objects/persons set dipswitch 10 "ON".
The sensor only activates when a person or object stays in the detection area for more
then 2 seconds.
WARNING
Please do not set ON delay 2sec. to "ON" when door cancel function is "ON".
If both are "ON" , the sensor does not output signal unless it detects a person
Risk of getting caught.
or object more than 2sec and 1st row is inactive.
If the person or object enter the fist row, the sensor does not detect and door
never opens.
3-7.Setting the automatic infinite presence detection
When people or objects enter more than 2 spot areas, this function automatically sets the presence
detection timer to infinity to increase safety and avoid unwanted door opening due to sudden change
in floor condition.
3-8.Setting the presence area
With dipswitch 12 "1st & 2nd" , presence detection timer for 1st & 2nd rows belong to
dipswitch 3 and 4. Presence detection timer for 3th to 5th row automatically becomes 2 sec..
With dipswitch 12 "1st to 5th" , presence detection timer will be same as all detection area,
set by combining dipswitch 3 and 4.
NOTE
When dipswitch 11 is set to "ON" the automatic infinite presence detection has priority over this function.
3-9.Setting the outputs
The activation and safety outputs can be selected separately
( N.C. or N.O. by dipswitch 13 and 14 )
The output timing from "Activation output" and "Safety output" can be changed
by dipswitch 15.
With dipswitch 15 set to "ON" the output timing will be the same.
With dipswitch 15 set to "OFF" the output timing will be different.
See CHECKING.
All manuals and user guides at all-guides.com
Front view
[mm(feet,inch)]
2.0
(6'7")
3.0
(9'10")
4.0
(13'2")
1
2
3 4 5
6
7
8 9 10 11
12
4.5
(14'9")
0
3.0
2.0
1.0
1.0
2.0
(9'10")
(6'7")
(3'3")
(3'3")
(6'7")
.
10 11 12
12
: Presence area
13
: Activation output
14
: Safety output
15
: Simultaneous output
: Door cancel function
16
: N/A
: ON delay
:Automatic infinite
presence detection
Low
Middle
High
S-High
1
2
1
2
1
2
2sec.
60sec. 10min.
3
4
3
4
3
4
Setting1
Setting2
Setting3
Setting4
5
6
5
6
5
6
5rows
4rows
3rows
2rows
7
8
7
8
7
8
7
ON
9
ON
10
ON
11
1st & 2nd 1st to 5th
12
Activation output
Safety output
N.C.
N.O.
N.C
13
13
14
Simultaneous
output
ON
15
CHECKING
Check the operation according to the chart below.
Entry
Power OFF
Status
Image
Operation indicator
None
N.O.
Activation
13
Simultaneous
N.C.
output
output
3.0
OFF
(9'10")
13
N.O.
15
Safety
14
N.C.
output
14
N.O.
Activation
13
Simultaneous
N.C.
output
output
ON
13
N.O.
15
Safety
14
N.C.
output
14
INFORM BUILDING OWNER / OPERATOR OF THE FOLLOWING ITEMS
WARNING
1. Always keep the detection window clean. If dirty, wipe the window with a damp cloth.(Do not use any cleaner / solvent.)
1
2
2. Do not wash the sensor with water.
3. Do not disassemble, rebuild or repair the sensor yourself, otherwise electric shock may occur.
4. When the operation indicator is twice geen blinking, contact your installer or service engineer.
5. Always contact your installer or service engineer when changing the settings.
6. Do not paint the detection window.
1. When turning the power on, always walk-test the detection area to ensure the proper operation.
NOTE
2. Do not place any objects that move or emit light in the detection area. (e.g. Plant, illumination, etc.)
Alarm display
Refer to the TROUBLESHOOTING below when the following appears.
3
4
Status
Life cycle notification
Twice green blinking
Operation indicator
TROUBLESHOOTING
Door Operation Operation
5
6
indicator
None
Wrong power supply voltage.
Door does not
open when a
Wrong wiring or connection failure.
person enters
Unstable
Wrong detection area positioning.
the detection
Sensitivity is too low.
area.
8
Short presence detection timer.
Dirty detection window.
Green
Wrong (Safety/Activation) output setting.
OFF
Both ON delay and door cancel function
are "ON".
9
Orange
Wrong wiring.
The detection area overlaps
Door opens
Unstable
with that of another sensor.
when no one
is in the
Water drops on the detection window.
detection area.
(Ghosting)
The detection area overlaps
with the door / header.
Sensitivity is too high.
Wrong (Safety/Activation) output setting.
OFF
Door remains
Presence timer is "
Proper
open
sudden change in the detection area
10
happened.
Wrong wiring or connection failure.
The automatic infinite presence
detection is "ON" and the objects or
people enter more than two spot areas.
Green
Wrong (Safety/Activation) output setting.
Proper
Twice
Output relay(s) is reaching the end of
Green
its life cycle.
blinking
Slow
Signal saturation
OFF
Green
blinking
The detection area overlaps with
11
the door / header.
12
N.O
Manufacturer
OPTEX Co.,LTD.
5-8-12 Ogoto Otsu 520-0101, Japan
14
TEL.: +81(0)77-579-8700
FAX.: +81(0)77-579-7030
WEBSITE: www.optex.co.jp/as/eng/index.html
North and South America Subsidiary
OPTEX Technologies Inc.
OFF
Corporate Headquarters
3882 Del Amo Blvd., Suite 604 Torrance, CA 90503 U.S.A.
TOLL-FREE: +1-800-877-6656
FAX.: +1(310)214-8655
15
WEBSITE: www.optextechnologies.com
Outside of
Entry into
Entry into
detection
2nd row
3rd to 5th row
area
Motion / Presence
-
Stand-by
detection active
Orange
Green
Signal Saturation
Slow green blinking
Possible countermeasures
Possible cause
Set to the stated voltage.
Check the wires and connector.
Check DETECTION AREA & ADJUSTMENTS
Set the sensitivity higher.
Set the presence detection timer longer.
Wipe the detection window with a damp cloth.
(Do not use any cleaner or solvent.)
Check ADJUSTMENTS 3-9.
Set either function to "OFF"
Check ADJUSTMENTS 3-5 & 3-6.
Check the wires and connector.
Check ADJUSTMENTS 3-3.
Use the rain-cover (Separately available).
Or install the sensor in a place keeping the water
-drops off.
Adjust the detection area to "Deep" (Outside).
Set the sensitivity lower.
Check ADJUSTMENTS 3-1.
Check ADJUSTMENTS 3-9.
Check ADJUSTMENTS 3-2 & 3-7.
" and
If the problem still persists, hard-reset the
sensor.(Turn the power OFF and ON again.)
Check the wires and connector.
Remove the objects.
Or check ADJUSTMENTS 3-7.
Check ADJUSTMENTS 3-9.
Replace the sensor.
Remove highly reflecting objects from the
detection area.Change the area angle.
Adjust the detection area to "Deep" (Outside).
European Subsidiary
OPTEX Technologies B.V.
Henricuskade 17, 2497 NB The Hague,The Netherlands
TEL.: +31(0)70-419-4100
FAX.: +31(0)70-317-7321
E-MAIL: info@optex.eu
WEBSITE: www.optex.eu
East coast office
8510 McAlpines Park Drive, Suite 108 Charlotte,
NC 28211 U.S.A.
TOLL-FREE.: +1-800-877-6656
WEBSITE: www.optextechnologies.com
Outside of
Entry into
detection
1st row
area
Stand-by
Red
Green
FAX.: +1(704)365-0818

Advertisement

loading

This manual is also suitable for:

Oa-4500se