Alternating Current - Minimum Distances; About This Manual - Jet JWS Series Operating Instructions And Parts Manual

Web strap ratchet hoists
Table of Contents

Advertisement

32. The fiberglass handle has been tested and
meets certain insulating properties of a "hot
stick". However, the web strap on this hoist is
not a rated insulating member. The web strap,
when clean and dry, may have dielectric
properties typical of polyester or nylon fibers.
Use appropriate insulating members in series
with this hoist to achieve proper working
Voltage range
(phase to phase)
Kilovolt
2.1 to 15
15.1 to 35
35.1 to 46
46.1 to 72.5
72.6 to 121
138 to 145
Familiarize yourself with the following safety notices used in this manual:
This means that if precautions are not heeded, it may result in minor injury and/or
possible tool damage.
This means that if precautions are not heeded, it may result in serious, or possibly even
fatal, injury.

2.0 About this manual

This manual is provided by JET, covering the safe operation and maintenance procedures for a JET JWS-series
Web Strap Ratchet Hoist. This manual contains instructions on safety precautions, general operating procedures,
maintenance instructions and parts breakdown. This tool has been designed and constructed to provide
consistent, long-term operation if used in accordance with the instructions set forth in this document.
The web strap hoists are proof-tested and comply with OSHA, ANSI/ASME B30.21 Lever Hoists and
B30.10 Hooks standards.
If there are questions or comments, please contact your local supplier or JET. JET can also be reached at our
web site: www.jettools.com.
Retain this manual for future reference. If the hoist transfers ownership, the manual should accompany it.
Read and understand the entire contents of this manual before attempting setup or
operation! Failure to comply may cause serious injury!
1.1 Alternating Current – Minimum Distances
(OSHA Regulation Subpart V, 1926.950 Table V-1)
Minimum
Working & Clear
Hot Stick
Distance
2 ft. 0 in.
2 ft. 4 in.
2 ft. 6 in.
3 ft. 0 in.
3 ft. 4 in.
3 ft. 6 in.
SAVE THESE INSTRUCTIONS
distances per OSHA Regulation Subpart V,
1926.950 (see Table 1) or follow your
company's safe work practices. If handle
swings closer to energized conductors than
OSHA working distances or company practices
permit, use appropriate rubber gloves rated for
the voltage.
Voltage range
(phase to phase)
Kilovolt
161 to 169
230 to 242
345 to 362
500 to 552
700 to 765
Table 1
3
Minimum
Working & Clear
Hot Stick
Distance
3 ft. 8 in.
5 ft. 0 in.
7 ft. 0 in.
11 ft. 0 in.
15 ft. 0 in.

Advertisement