Troubleshooting - Projecta INTELLI JAY PM100-BTJ Manual

12v power management system
Table of Contents

Advertisement

4.2 Troubleshooting

MAINS.
VEHICLE
CHARGE
BATTERY
TROUBLESHOOTING
FAULT
DESCRIPTION
"FAULT" flashes once every sec.
House battery low voltage alarm.
10V≤ House battery voltage <10.5V.
No starter battery connected.
"FAULT" flashes once every sec.
"Vehicle Bat."flashes twice every sec.
House battery low voltage alarm.
10V≤ House battery voltage <10.5V.
Vehicle battery has been connected,
but VCR disconnect.
"FAULT" flashes twice every cycle.
House battery high voltage alarm.
House battery voltage≥16V.
No vehicle battery connected.
"FAULT" flashes twice every cycle.
House battery high voltage alarm.
House battery voltage≥16V.
Vehicle battery has been connected.
"FAULT" flashes 3 times every cycle.
PM100J unit over temp alarm.
PM100J is working under PS mode.
"FAULT" flashes 3 times every cycle.
"Charge"flashes as 1 sec on then 2
sec off
PM100J unit over temp alarm.
PM100J is working under CHG mode.
"FAULT" flashes 4 times every cycle.
"Charge"flashes as 1 sec on then 2
sec off. Bulk charging time out alarm.
"FAULT" flashes 5 times every cycle.
"Charge" flashes once every sec.
VCR anomaly alarm.
"FAULT" flashes 6 times every cycle.
Environment over temp alarm.
PM100J is working under PS mode.
"FAULT" flashes 6 times every cycle.
"Charge"flashes as 1 sec on then
2 sec off. Environment over temp
alarm.
PM100J is working under CH mode.
SOLUTIONS
The house battery needs to be charged
as soon as possible.
The house battery needs to be charged
as soon as possible.
Please consult the distributor, installer or
PROJECTA
Please consult the distributor, installer or
PROJECTA
PM100J will restart automatically
Check the ventilation and try to
disconnect some of the less priority loads.
If the fault still exists, please contact the
distributor, installer or PROJECTA
1. Check the setting of the battery
capacity. It should match the actual
battery capacity.
2. Check the status of the battery.
If the battery is dead, please contact the
battery manufacturer or distributor.
Please consult the distributor, installer or
PROJECTA
PM100J will restart automatically
PM100J will restart automatically
13

Advertisement

Table of Contents
loading

Table of Contents