x-sense XP01 User Manual

x-sense XP01 User Manual

Combination smoke and carbon monoxide alarm
Hide thumbs Also See for XP01:

Advertisement

Quick Links

Combination Smoke and Carbon
Monoxide Alarm
User Manual
XP01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XP01 and is the answer not in the manual?

Questions and answers

Dr Reddy
June 17, 2025

It was hardly 2 years since installation and its already bleeping intermittently denoting loss of battery power. Can we not replace batteries for X-SENSE MODEL: XP01? If so how to re-order, it seems unavailable in market?

Subscribe to Our Youtube Channel

Summary of Contents for x-sense XP01

  • Page 1 Combination Smoke and Carbon Monoxide Alarm User Manual XP01...
  • Page 2 NEVER IGNORE THE SOUND OF THE ALARM! • Leaving children unsupervised. Determining what type of alarm has sounded is easy with your X-Sense combination smoke & carbon • Cleaning with fl ammable liquids, such as gasoline. monoxide alarm. The alarm sounder will inform you of the type of situation occurring.
  • Page 3: Technical Speci Cations

    Technical Speci cations • Incendiary fires where the fire grows so rapidly that an occupant’s egress is blocked even with properly located detectors. Power supply 10-year sealed lithium battery WARNING: Sensor type Smoke: Photoelectric Actuation of your CO Alarm indicates the presence of Carbon Monoxide (CO) CO: Electrochemical which can kill you.
  • Page 4 CO silence mode: Press the test button during an alarm state, the unit will enter the silence mode. If MOISTURE. DO NOT KNOCK OR DROP THE ALARM. DO NOT OPEN OR TAMPER WITH THE ALARM AS THIS COULD CAUSE MALFUNCTION. the CO density still exceeds the alarm threshold within 6 minutes, the unit will enter another alarm state.
  • Page 5: Basic Safety Information

    Di erent working modes and states are shown in the below table: Low battery Flashes yellow once every One beep every 60 seconds. 60 seconds. Mode LED Indicator Audible Alarm Remarks Powering on Blinks 8 cycles 1 quick beep. Make sure the alarm is (red/green/yellow) in sequence.
  • Page 6 Ins tallation Instructions CAUTION! THIS SMOKE & CARBON MONOXIDE ALARM HAS TWO SEPARATE ALARMS WHICH WORK Installation Locations INDEPENDENTLY. THE CARBON MONOXIDE ALARM IS NOT DESIGNED TO DETECT FIRE OR ANY OTHER GAS. IT WILL ONLY INDICATE THE PRESENCE OF CARBON MONOXIDE GAS AT THE SENSOR. 1.
  • Page 7: Recommended Placement

    Recommended Placement WARNING! 1. THIS ALARM SHOULD BE INSTALLED BY A COMPETENT PERSON. 2. INSTALLATION OF THE ALARM SHOULD NOT BE USED AS A SUBSTITUTE FOR PROPER INSTALLATION, USE AND MAINTENANCE OF FUEL BURNING APPLIANCES INCLUDING APPROPRIATE VENTILATION AND EXHAUST SYSTEMS. How to Install This Alarm IMPORTANT! THIS COMBINATION SMOKE/CO ALARM IS DESIGNED TO BE MOUNTED ON THE CEILING OR WALL.
  • Page 8: Locations To Avoid

    Locations to Avoid Note WARNING - This product is intended for use in ordinary indoor locations of family living units. It is When attaching the alarm to the mounting bracket, twist the alarm clockwise fi rst, then fi rmly press not designed to measure compliance with the occupational safety and health administration (OSHA) down on the alarm and rotate until it locks into place without any gaps.
  • Page 9: Maintenance

    2. NEVER USE A VEHICLE EXHAUST TO TEST THIS UNIT. EXHAUST FUMES MAY CAUSE PERMANENT Everyone is susceptible to the danger of CO, but experts agree that unborn babies, small children, DAMAGE AND VOID YOUR WARRANTY. pregnant women, senior citizens and people with heart or respiratory problems are at the highest risk for serious injury or death.
  • Page 10: Troubleshooting

    Check whether the alarm is properly attached to the mounting Manufacturer and Service Information bracket. X-Sense Innovations Co., Ltd. Address: B4-503-D, Tower B, Kexing Science Park, No. 15 Keyuan Road, Technology Park Community, Make sure you have pushed the Test button fi rmly.
  • Page 11 Email: support@x-sense.com X-Sense Innovations Co., Ltd.