Advertisement

Quick Links

Technical Reference Manual
TM
The DISTO
OEM module 3.0 is a powerful, easy to integrate distance measuring module. Due to safety aspects
(e.g. laser safety, labeling, ...), system integration is limited to companies which are qualified to integrate such
modules into their own housing and/or complete system.
Therefore this module is not intended to be sold as a final product or for any purposes other than the above-
mentioned.
Distance Reference
Type:
DISTO
Art. No.:
724866
Type:
DISTO
Art. No.:
563890
Leica Geosystems AG CH-9435 Heerbrugg
1/12
725538.doc
TM
TM
TM
TM
DISTO
DISTO
OEM module 3.0 WH15/WH30
OEM module 3.0 WH15/WH30
DISTO
DISTO
OEM module 3.0 WH15/WH30
OEM module 3.0 WH15/WH30
TM
OEM module 3.0 WH15
TM
OEM module 3.0 WH30
08.11.01
Laser beam outlet
V1.20

Advertisement

Table of Contents
loading

Summary of Contents for Leica Geosystems DISTO WH15

  • Page 1 Therefore this module is not intended to be sold as a final product or for any purposes other than the above- mentioned. Distance Reference Laser beam outlet Type: DISTO OEM module 3.0 WH15 Art. No.: 724866 Type: DISTO OEM module 3.0 WH30 Art. No.: 563890 Leica Geosystems AG CH-9435 Heerbrugg 1/12 725538.doc 08.11.01...
  • Page 2: Table Of Contents

    DISTO DISTO OEM module 3.0 WH15/WH30 OEM module 3.0 WH15/WH30 DISTO DISTO OEM module 3.0 WH15/WH30 OEM module 3.0 WH15/WH30 Technical Reference Manual V1.20 Contents: TECHNICAL DATA................................3 PHYSICAL DIMENSIONS AND FIXING..........................4 INTERFACE PARAMETERS..............................5 3.1..............................5 OFTWARE PARAMETERS 3.2........................5 IN ASSIGNMENT OF THE SUB CONNECTOR POWER ON /OFF ................................6 SOFTWARE INTERFACE PROTOCOL ..........................6...
  • Page 3: Technical Data

    DISTO DISTO OEM module 3.0 WH15/WH30 OEM module 3.0 WH15/WH30 DISTO DISTO OEM module 3.0 WH15/WH30 OEM module 3.0 WH15/WH30 Technical Reference Manual V1.20 1. Technical data Typical measuring accuracy for WH15 +/- 1.5 mm Typical measuring accuracy for WH30 +/- 3 mm Maximum measuring accuracy for WH15 +/- 2 mm...
  • Page 4: Physical Dimensions And Fixing

    DISTO DISTO OEM module 3.0 WH15/WH30 OEM module 3.0 WH15/WH30 DISTO DISTO OEM module 3.0 WH15/WH30 OEM module 3.0 WH15/WH30 Technical Reference Manual V1.20 2. Physical dimensions and fixing When fixing the Module you have to be careful not to point the instrument directly toward the sun.
  • Page 5: Interface Parameters

    DISTO DISTO OEM module 3.0 WH15/WH30 OEM module 3.0 WH15/WH30 DISTO DISTO OEM module 3.0 WH15/WH30 OEM module 3.0 WH15/WH30 Technical Reference Manual V1.20 3. Interface parameters 3.1. Software parameters The interface of the DISTO OEM module 3.0 has been arranged so that it can be connected to a PC by means of an adapter.
  • Page 6: Power On /Off

    DISTO DISTO OEM module 3.0 WH15/WH30 OEM module 3.0 WH15/WH30 DISTO DISTO OEM module 3.0 WH15/WH30 OEM module 3.0 WH15/WH30 Technical Reference Manual V1.20 4. Power on /off • Pin 13 of the D-sub Connector is Open (Tristate): To switch the module on, use command “a” (See 6.2.1 RESET command (a) on page 9). To switch the module off, use the command “b”...
  • Page 7: Word Indexes (Wi)

    DISTO DISTO OEM module 3.0 WH15/WH30 OEM module 3.0 WH15/WH30 DISTO DISTO OEM module 3.0 WH15/WH30 OEM module 3.0 WH15/WH30 Technical Reference Manual V1.20 Position Description: Remark Word index 00-99 With zeroes at start no significance In service mode as expansion of word index Attribute 0: Measured value 1: Manually-entered value...
  • Page 8: Error Reports

    Prohibited parameter in command entry, or prohibited command, or non-valid @E203 result Parameter set-up incorrect (Contact Leica Geosystems) @E217 Parity error (Prior to contacting Leica Geosystems please check the Terminal @E221 settings) Interface buffer overflow (Contact Leica Geosystems if error occurs when sending less than 24...
  • Page 9: Commands

    DISTO DISTO OEM module 3.0 WH15/WH30 OEM module 3.0 WH15/WH30 DISTO DISTO OEM module 3.0 WH15/WH30 OEM module 3.0 WH15/WH30 Technical Reference Manual V1.20 6. Commands 6.1. General After a command has been entered, it is decoded and processed. If additional commands are sent, processing of the current command will be aborted if possible and the last command to be received will be processed.
  • Page 10: Tracking (H)

    DISTO DISTO OEM module 3.0 WH15/WH30 OEM module 3.0 WH15/WH30 DISTO DISTO OEM module 3.0 WH15/WH30 OEM module 3.0 WH15/WH30 Technical Reference Manual V1.20 6.2.7. Tracking (H) Function: Triggers continuous measurement of distance. The measurements are continued until the next command is issued or until a fault arises.
  • Page 11: Setting Baud Rate (70)

    DISTO DISTO OEM module 3.0 WH15/WH30 OEM module 3.0 WH15/WH30 DISTO DISTO OEM module 3.0 WH15/WH30 OEM module 3.0 WH15/WH30 Technical Reference Manual V1.20 6.2.16. Setting baud rate (70) Function: Sets the baud rate with fixed parity (none parity). GSI IN: N70N%N<trm>...
  • Page 12: Validity

    To get this information refer to 6.2.11 Software version (00) on Page 10. Leica Geosystems AG DISTO CH-9435 Heerbrugg 725538-1.2.0en (Switzerland) Phone ++41 71 727 31 31 Fax ++41 71 727 46 73 Printed in Switzerland Copyright Leica Geosystems AG, Heerbrugg, Switzerland 2001 www.leica-geosystems.com 12/12 725538.doc 08.11.01...

This manual is also suitable for:

Disto wh30

Table of Contents