AWA, TWA, CH AWA, CH TWA, Ground Wind
AWA, TWA, CH AWA, CH TWA, Ground Wind
AWA, TWA, CH AWA, CH TWA, Ground Wind
AWA, TWA, CH AWA, CH TWA, Ground Wind
AWA, TWA, CH AWA, CH TWA, Ground Wind
Press the Menu/Back key
Wind Speed
Wind Damping (0 to 12s, 3s)
Adjust (W Speed) (0.3 to 2.5, 1.0)
Max TWS Alarm
Wind Angle
W Angle Response (0 to 12s, 4s)
Offset(W Angle) (-179° to +180°, 0°)
Wind Shift Alarm
High AWA Alarm
Low AWA Alarm
Engine
Engine
Engine
Engine
Engine
Press the Menu/Back key
Engine
Engine Assign (1 to 4, 1), Where [Number of Engine] = 1
Engine PORT (1 to 4, 1), Where [Number of Engine] = 2 or 3
Engine STBD (1 to 4, 2), Where [Number of Engine] = 2 or 3
Engine Center (1 to 4, 3), Where [Number of Engine] = 3
Engine Alarm
1Graph, 2Graphs
1Graph, 2Graphs
1Graph, 2Graphs
1Graph, 2Graphs
1Graph, 2Graphs
Press the Menu/Back key
*
Depth Graph
Period (5min, 30min, 1h, 3h, 6h, 12h, 1d, 2d, 3d, 7d)
Range (15 to 4921ft, 1500ft)
W.Temp
Period (5min, 30min, 1h, 3h, 6h, 12h, 1d, 2d, 3d, 7d)
Graph*
Range (9°F to 369°F, 9°F)
A Temp.
Period (5min, 30min, 1h, 3h, 6h, 12h, 1d, 2d, 3d, 7d)
Graph
*
Range (9°F to 369°F, 9°F)
Air Temp. Offset (-99.9°C to 99.9°C, 0°C)
A. Press
Period (5min, 30min, 1h, 3h, 6h, 12h, 1d, 2d, 3d, 7d)
Graph*
Range (5 to 50hPa, 10hPa)
Air Press. Offset (-99.9hpa to 99.9hpa, 0hpa)
*
: Depends on displayed graph data
AIS
AIS
AIS
AIS
AIS
Press the Menu/Back key
AIS
Orientation (North Up, Heading Up)
CPA TCPA Alarm
ICOM AIS Data (Yes, No)
Custom Box
Custom Box
Custom Box
Custom Box
Custom Box
Press the Menu/Back key
Heading* (See previous page)
STW* (See previous page)
SOG* (See previous page)
Wind Speed* (See above menu tree)
Wind Angle* (See above menu tree)
Engine* (See above menu tree)
Trip*
Clear (Yes, No)
Trip Alarm
*: Dependant on data displayed in custom box.
Alarm (OFF, ON: 0.0 to 99.9kn, 19.4kn)
Buzzer (Short, Middle, Long, Continue)
Alarm (OFF, ON)
Buzzer (Short, Middle, Long, Continue)
Alarm (OFF, ON: 0 to S179°, S60°)
Buzzer (Short, Middle, Long, Continue)
Alarm (OFF, ON: P1 to P180°, P60°)
Buzzer (Short, Middle, Long, Continue)
Alarm (OFF, ON)
Buzzer (Short, Middle, Long, Continue)
Alarm (OFF,ON)
CPA (0 to 6.00NM, 0.00NM)
TCPA (30sec, 1min, 2min, 3min, 4min, 5min, 6min, 12min)
Buzzer (Short, Middle, Long, Continue)
Alarm (OFF, ON:0 to 9999NM; 0NM)
Buzzer (Short, Middle, Long, Continue)