Download Print this page

ADTRAN Total Access 334 Manual page 3

Indoor 3rd generation sfu ont with rf
Hide thumbs Also See for Total Access 334:

Advertisement

Figure 3. Connecting SC Connector
3. Clean the ends of the incoming fiber and the SC Connection.
4. Connect the incoming fiber cable to the SC connection.
5. Route the fiber cable through the slot in the protective cover
and slide it back in place.
6. Replace and secure the panel using the phillips-head screw.
Installing Power
Plug the supplied 12V AC/DC Power Converter into the
connection on the rear of the chassis. Connect the power plug to a
standard 120 VAC outlet.
Using a UPS
The SFU ONT can typically use an un-interruptible power supply
UPS
(
) if desired. Power is supplied to the SFU ONT by a local power
source with battery backup that utilizes the AC power at the
customer premises. The UPS powers the SFU ONT and functions as a
BBU supplying continuous 12 VDC. Refer to the installation material
that is provided with the UPS when installing the BBU.
Connecting UPS
Connect the UPS to the 8-pin MOLEX connector labeled "UPS"
located on the rear of the SFU ONT chassis.
UPS MOLEX connector.
8
7
4
3
3
4
Figure 4. UPS Connector
The UPS Power/Alarm Connections Table at the top on the next
column defines each pin on the connector.
Coaxial Connection
Refer to the first illustration in this Job Aid and connect the coaxial
cable to the connector labeled
61287736G3-22B
SC Connector
Protective
Note:
This illustration may not
Cover
match your ONT, but the
Fiber Installation is the same.
PWR
Figure 4
represents the
6
5
2
1
CATV
on the rear of the SFU ONT.
UPS Power/Alarm Table
The table below provides a pin-out for the UPS connector.
Pin-Out
Description
1
Power Input (+12 VDC)
2
UPS Status - On Battery
3
UPS Status - Battery Missing
4
Signal Return
5
Power 12V Return
6
UPS Status - Replace Battery
7
UPS Status - Low Battery
8
No Connection
ON/OFF Button
An On/Off button is located on the far-left side of the rear of the SFU
ONT. User functionality is limited to this button.
NOTE
If a BBU is being used and is disconnected, the SFU ONT is not
protected from power outages, and will send a "Battery Missing"
alarm to the OLT.
LED S
TATUS
The LEDs are located beneath the plastic housing and are only visible
after power has been applied. The following table provides the LED
status during normal operations.
Label
Status
PWR
Off
Green
BATTERY
Off
Green
2
Green Flashing
Slow
2
Green Flashing Fast
LOS
Off
Red
Red Flashing Slow
2
2
Red Flashing Fast
ETH 1-4
Off
Green
2
Green Flashing Fast
MGMT
Off
Green
POTS 1-2
Off
Green
2
Green Flashing
Slow
WLAN
Not supported
Alarm
-
1
2
-
-
3
4
-
Indication
AC or battery off
AC or battery power valid
ONT boot or battery missing or
not equipped
Battery equipped and no bat-
tery alarms present
Loss of AC, on battery
Battery low
DS signal detected and is
within margins
No DS signal detected
DS signal is present but mar-
ginal
Software Upgrade failed
Link is down or not equipped
Link is up but no data activity
Data is being sent or received
MGMT channel not active
MGMT channel active
Unequipped or on-hook and
not ringing
One of more lines off-hook
All line on-hook with one of
more lines in ringing state
3

Advertisement

loading

This manual is also suitable for:

1287736g3