Audio detector

Advertisement

Specifications

Frequency: 345MHz
Battery: 3V lithium CR123A
Battery life: 5 years
Detection distance: 6 in max

Operation

The FireFly is designed to listen to the alarm sounder of any smoke detector. Once confirmed as
an alarm, it will transmit a signal to the alarm control panel which if connected to a central
monitoring station, will dispatch the fire department.

Enrolling

To enroll the sensor, set your panel into program mode, refer to your specific alarm panel manual
for details on these menus. For panels with a learn feature, once prompted by the control panel,
press the small button located on the device to trigger a transmission. Or you can manually enter
the serial number printed on the back of each unit. This product enrolls as a 5816 and uses Loop 1
to transmit alarm signals.

Mounting

Included with this device is a mounting bracket, hardware and double sided tape. To ensure
proper operation ensure the side of the device with the small holes is directly facing the sounder
holes on the smoke detector. The FireFly must be mounting within 6 inches of the detector for
optimal operation.

Testing

To test the RF transmission from the mounted position you can either generate a tamper by
removing the cover or press the small button within the device. This will send a signal to the
control panel. To test the audio detection, press and hold the smoke detector test button. Ensure
the FireFly cover is on and that you wear hearing protection. When a signal is detected the LED on
the device will start to flash, once it has determined it's a valid smoke alarm signal the LED will
turn on steady and transmit a signal to the control panel.

Replacing the Battery

When the battery is low a signal will be sent to the control panel. To replace the battery:
1.
Remove the top cover to reveal the battery. This will send a tamper signal to the control
panel.
2.
Replace with a Panasonic CR123A battery ensuring the + side of the battery faces as
indicated on the device.
3.
Re-attached the cover, you should hear a click when the cover engages properly.
Audio Detector WST-602
Operating Temperature: 32°-120°F (0°-49°C)
Operating Humidity: 5-95% RH non condensing
Compatible with 2GIG and Honeywell receivers
Supervisory signal interval: 64 min(approx.)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Firefly WST-602 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ecolink Firefly WST-602

  • Page 1 Audio Detector WST-602 Specifications Frequency: 345MHz Operating Temperature: 32°-120°F (0°-49°C) Battery: 3V lithium CR123A Operating Humidity: 5-95% RH non condensing Battery life: 5 years Compatible with 2GIG and Honeywell receivers Detection distance: 6 in max Supervisory signal interval: 64 min(approx.) Operation The FireFly is designed to listen to the alarm sounder of any smoke detector.
  • Page 2 IC:9863B-WST602 Warranty Ecolink Intelligent Technology Inc . warrants that for a period of 5 years from the date of purchase that this product is free from defects in material and workmanship. This warranty does not apply to damage caused by shipping or handling, or damage caused by accident, abuse, misuse, misapplication, ordinary wear, improper maintenance, failure to follow instructions or as a result of any unauthorized modifications.

Table of Contents