13. Viewing the test results.
The log data that was obtained by the ATS2 macro must be evaluated by opening the Excel
sheet that was described in section "4-10. Pass/Fail evaluation and report of this test."
Device under test
Serial Number
ESP-1
Lot
Date of test
2005,03,13
Tester's Name
AMPL
Nois
FRQ20K
5-1.(GV=0dB)
FRQ20
THDN
When this sheet shows that the unit has passed test, it can be returned to the customer.
If the test is failed, retest or repair the ESP.
Device under test
Serial Number
Lot
Date of test
Tester's Name
AMPL
Nois
FRQ20K
5-1.(GV=0dB)
FRQ20
THDN
Print out the results of the Excel sheet and place it with the unit to be shipped back to the
customer. The passed Excel test sheet and text (.txt) log file should be archived so that there is
a record of the unit passing test.
TEST PROCEDURES
CH1
CH2
CH3
4.17
4.02
3.94
-80.03
-80.13
-80.05
3.39
3.08
3.05
3.66
3.50
3.41
0 0067 0 0068 0 0076 0 0075 0 0068 0 0068 0 0067 0 0067
CH1
CH2
CH3
96
According to OT1-400338
Result
CH4
CH5
CH6
4.11
3.92
3.94
-80.04
-81.30
-81.23
3.15
2.87
2.98
3.61
3.44
3.47
According to OT1-400338-1
Result
CH4
CH5
CH6
Passed
CH7
CH8
4.00
3.95
-81.30
-81.32
2.74
3.04
3.54
3.48
FAIL
CH7
CH8

Advertisement