Bose ControlSpace ESP-88 Service Manual page 83

Engineered sound processor
Hide thumbs Also See for ControlSpace ESP-88:
Table of Contents

Advertisement

This is an example of the PASSED ESP-88 chassis test data in Excel format.
5. Testing method and criteria.
Note: The information in the following pages is provided for reference only. You will not need to
set the ATS2 manually to perform these tests.
This section describes the settings and criteria of each of the tests to be performed.
The setting of the ATS-2 test station will be done automatically by the ATS2 Macro.
5-1. Gain at 0dB
ESP Setting: Set all channel gains to = 0dB. (Command on COM = ^BA{1/2}{L/R}00^C)
AMPL(1kHz)
ATS2 Settings
Item
Frequency
Amplitude
B/W
Filter
Test Limits
Item
Level
TEST PROCEDURES
Setting
1kHz
+4.00dBu
<10HZ / FS/2
None
Upper limit
+5.5dBu
83
Lower limit
+2.5dBu