TEST PROCEDURES
4-7. Phantom Power test on the ATS2.
The Phantom test is done by the Phantom checker hardware.
This test will proceed automatically.
4-8. RS485 test on the ATS2.
The RS485 test is performed by checking to see if the unit can see the CC-16 controller that is
connected to the RS485 connector.
The CC-16 icon will appear in the ControlSpace
®
test window when the CC-16 is connected to
ESP-88.
This test will proceed automatically.
When "EC16" is detected, "Pass" is logged to the log file automatically.
When "EC16" is not detected, "Fail" is logged to the log file automatically.
The address of the CC-16 should set anywhere from 1 to 15. Refer to the diagram below.
When the CC-16 controller is detected by the software through the chassis, this test will pass.
CC-16 DIP Switch Settings