Energy Hub Inverter Troubleshooting - SolarEdge RESU10H Prime Series Installation Manual

Single phase energy hub inverter with prism technology
Table of Contents

Advertisement

68
  Energy Hub Inverter Troubleshooting

Energy Hub Inverter Troubleshooting

Malfunction Description or
Possible Cause
Battery SOE 
Continuous
(state of
discharge; no
energy) is
charging
below 10%,
 
while solar
power is
being
produced
No power to
The loads are
backed-up
not backed up.
loads during
a power
outage
The inverter
External
does not
shutdown is on.
turn on.
Battery self-
Wrong battery
test failed
connections
Error 3x6B
Battery
communication
error
Error 3x6C
Battery internal
error
Single Phase Energy Hub Inverter with Prism Technology MAN-01-00842-1.3
Corrective Action
Preform a battery self-test as explained in Running a
Battery Self-test on page 55. If the battery self-test is
successfully passed, contact SE support.
Check the following:
The inverter is producing power.
The Backup function is enabled, as explained in
Enabling StorEdge Applications on page 55.
No error messages are displayed in SetApp.
Backed-up load circuit breakers are on.
The Backup Interface is in the Backup mode (the green
LED on the Backup Interface is continuously ON).
If an external shutdown switch is installed, make sure it
is in the ON position.
If no external shutdown switch is installed, make sure
the external shutdown short circuit jumper in the
Backup Interface is installed.
Make sure the DC cables, RS485 and En wires between
the battery and inverter are correctly connected.
Make sure the RS485 and En wires between the battery
and inverter are correctly connected.
Make sure the battery is correctly configured, as
explained in Configuring Communication with Other
Devices on page 54.
Contact SolarEdge support.