Mitsubishi Electric Mr.Slim PUZ-SM100VKA Service Manual page 79

Hide thumbs Also See for Mr.Slim PUZ-SM100VKA:
Table of Contents

Advertisement

SW2 setting
The number of connected indoor units
ON
1
2 3 4 5 6
Capacity setting display
ON
1
2 3 4 5 6
Outdoor unit setting information
ON
1
2 3 4 5 6
Indoor pipe temperature / Liquid (TH2(1))
Indoor 1
ON
- 39 to 88
1
2 3 4 5 6
Indoor pipe temperature / Cond. / Eva.
(TH5(1))
ON
Indoor 1
- 39 to 88
1
2 3 4 5 6
Indoor pipe temperature / Liquid (TH2(2))
Indoor 2
ON
- 39 to 88
1
2 3 4 5 6
Indoor pipe temperature / Cond. / Eva.
(TH5(2))
ON
Indoor 2
- 39 to 88
1
2 3 4 5 6
Indoor room temperature (TH1)
8 to 39
ON
1
2 3 4 5 6
OCH708
Display detail
79
The black square ( ) indicates a switch position.
Explanation for display
0 to 4
(The number of connected indoor units are dis-
played.)
Displayed as an outdoor capacity code.
Capacity
Code
SM100
20
SM125
25
SM140
28
• The tens digit (Total display for applied setting)
Setting details
H·P/Cooling only
0: H·P
Single phase/3 phase
0: Single phase 2: 3 phase
• The ones digit
Setting details
Defrosting switch
0: Normal
(Example) When heat pump, 3 phase and defrosting
(normal) are set up, "20" is displayed.
- 39 to 88
(When the temperature is 0: or less, "–" and
temperature are displayed by turns.)
- 39 to 88
(When the temperature is 0: or less, "–" and
temperature are displayed by turns.)
- 39 to 88
(When the temperature is 0: or less, "–" and
temperature are displayed by turns.)
- 39 to 88
(When the temperature is 0: or less, "–" and
temperature are displayed by turns.)
8 to 39
Code
display
Display details
1: Cooling only
Code
display
Display details
1: For high humidity
Unit
Unit
:
:
:
:
: