4-4. STANDARD OPERATION DATA
PUZ-SM100VKA.TH
PUZ-SM125VKA.TH
PUZ-SM140VKA.TH
Representative matching
Mode
Total
Capacity
input
Electrical
Indoor
circuit
Phase, Hz
Voltage
Current
Outdoor
Phase, Hz
Voltage
Current
Refrigerant
Discharge Pressure
circuit
Suction pressure
Discharge temperature :
Condensing temperature :
Suction temperature
Ref. pipe length
Indoor
Intake air
side
temperature
Discharge air
temperature
Outdoor
Intake air
side
temperature
SHF
BF
The unit of pressure has been changed to MPa based on international SI system.
The conversion factor is : 1(MPa)=10.2(kgf/cm²)
OCH708
PUZ-SM100YKA.TH
PUZ-SM125YKA.TH
PUZ-SM140YKA.TH
PUZ-SM100
COOLING
W
9.5
kW
2.79
PLA-SM100EA
1, 50
V
230
A
0.46
PUZ-SM100VKA
PUZ-SM100YKA
1, 50
V
230
A
12.1/4.3
MPa
2.93
MPa
0.96
90.2
38.0
14.1
:
m
7.5
DB
27
:
WB :
19
DB
13.6
:
DB
35
:
WB :
24
0.77
0.16
PUZ-SM125
HEATING
COOLING
11.2
12.1
3.1
4.17
PLA-SM125EA
1, 50
230
0.44
0.66
PUZ-SM125VKA
PUZ-SM125YKA
3, 50
1, 50
400
230
13.4/4.8
17.4/6.3
2.70
3.12
0.70
0.89
88.7
89.4
44.7
39.8
1.3
7.9
7.5
20
27
14
19
40.1
11.9
7
35
6
24
0.72
0.10
15
PUZ-SM140
HEATING
COOLING
13.5
13.4
3.73
5.13
PLA-SM140EA
1, 50
230
0.64
0.66
PUZ-SM140VKA
PUZ-SM140YKA
3, 50
1, 50
400
230
15.6/5.6
22.3/8.1
2.62
3.28
0.69
0.84
81.7
91.0
43.5
40.3
0.0
5.6
7.5
20
27
14
19
41.7
11.3
7
35
6
24
0.70
0.10
HEATING
15.0
4.54
0.64
3, 50
400
19.0/6.9
2.79
0.66
88.7
45.9
−0.9
20
14
44.5
7
6