Venting Arrangements; Allowable Vertical Terminations For Gem54-Ng - Regency Gem54 Owners & Installation Manual

Hide thumbs Also See for Gem54:
Table of Contents

Advertisement

installation
The shaded area in the diagram shows all allowable
combinations of straight vertical and offset to vertical
terminations, using two 90
elbows, with Rigid Pipe Venting
o
Systems for Natural Gas. Two 45
elbow. Maximum of four 45
elbows allowed.
o
"THIS UNIT MUST ALWAYS
TERMINATE / VENT
DIRECTLY TO THE OUTDOORS."
Please note min. 0.3m between 90
is required.
Vent must be supported at offsets.
Firestops are required at each floor level and
whenever passing through a wall.
Maintain clearances to combustibles as listed in
the "Clearances" section.
Refer to the "Vent Restrictor Position" section
for details on how to change the vent restrictor
from the factory setting of Set 1 to Set 2 or Set 3
if required.
Note: Must use optional flue adaptor when using
Rigid Pipe (Part # 770-994).
24

VENTING ARRANGEMENTS

ALLOWABLE VERTICAL TERMINATIONS FOR GEM54-NG

elbows equal to one 90
o
o
elbows
o
2
4
0
40
38
36
34
32
30
Vent Restrictor on Set 3
28
26
24
22
Vent Restrictor on Set 2
20
18
16
14
12
10
8
6
4
2
0
Max. 10 (3m)(centerline to centerline)
Minimum length of pipe
between elbows 12 (305mm)
Horizontal (Feet)
8
6
10
12
Vent Restrictor on Set 1
(factory setting)
Gem 54 Regency Gas Fire
14
18
16
20

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gem54ng1-rGem54lpg1-rGem54ulpg1-r

Table of Contents