The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude. Open the air shutter for a blue flame or close
for a more yellow flame.
Minimum Air Shutter Opening:
NG
13mm
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
240 V AC
50 HZ
Part #: 909-185
Gem 54 Regency Gas Fire
AERATION ADJUSTMENT
LP
ULPG
CAUTION: Carbon will be produced if air shutter
WIRING DIAGRAM
Blue
(Neutral)
Yellow/Green
Brown
(Live)
Ground
Full open 22 mm
Full open 22mm
is not fully open.
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.
Fan
White
Red
Black
White
Fan Thermodisc
(Normally open)
Note: Any damage due to carboning
resulting from improperly setting
the aeration controls is NOT covered
under warranty.
Fan
Ground
HIGH
OFF
LOW
909-185
installation
33