4 Operation
3 Change the name and press
temperature schedules). Example: MyWeekSchedule
4.7.4
Predefined schedules: Room temperature
+ leaving water temperature (main)
: Desired temperature = Preset value (Comfort)
: Desired temperature = Preset value (Eco)
Predefined 1
Mon - Fri
07:00 09:00
Sat - Sun
08:00
Predefined 2
Mon - Fri
07:00 09:00
Sat - Sun
08:00
Predefined 3
Mon - Sun
08:00
INFORMATION
The predefined schedules are applicable for both heating
and cooling operation.
4.7.5
Predefined schedules: Leaving water
temperature (additional)
 : Additional zone = On
: Additional zone = OFF
Predefined 1
Mon - Fri
07:00 09:00
Sat - Sun
08:00
Predefined 2
Mon - Fri
07:00 09:00
Sat - Sun
08:00
Predefined 3
Mon - Sun
08:00
INFORMATION
The predefined schedules are applicable for both heating
and cooling operation.
User reference guide
18
. (Only applicable for room
17:00
23:00
23:00
12:00
14:00
17:00
23:00
23:00
23:00
17:00
23:00
23:00
12:00
14:00
17:00
23:00
23:00
23:00
4.7.6
Predefined schedules: DHW tank
temperature
a
: Start production of domestic hot water. Desired DHW  tank
temperature = Preset value (Storage comfort)
b
: Start production of domestic hot water. Desired DHW  tank
temperature = Preset value (Storage eco)
Predefined 1
a
Mon - Sun
b
Predefined 2
a
Mon - Sun
b
Predefined 3
a
Mon - Fri
b
a
Sat - Sun
b
4.8

Weather dependent operation

In space heating/cooling control, the leaving water temperature
setpoint mode can be:
▪ Fixed
▪ Weather-dependent (the leaving water temperature is determined
automatically depending on the outdoor temperature)
To select the setpoint mode, see the installer reference guide.
To set the parameters for the weather-dependent curve, see below.
4.8.1

To set the weather dependent settings

Prerequisite: You switched the permission level to Advanced end
user.
1 Go to [7.7]:
> User settings > Set weather dependent.
2 For main leaving water temperature zone [7.7.1], modify with
,
,
,
, and confirm with
3 If applicable, for additional leaving water temperature zone
[7.7.2], modify with
,
,
Set weather-dependent heating/Set weather-dependent cooling
T t
c
d
a
b
T
Target leaving water temperature
t
T
Outdoor temperature
a
a
Low outdoor ambient temperature
b
High outdoor ambient temperature
EBLQ+EDLQ011~016CAV3+W1 + EK(2)CB07CAV3 +
Daikin Altherma low temperature monobloc
:00
:00
:00
:00
:00
:00
.
,
, and confirm with
.
T a
EKMBUHCA3V3+9W1
4P522035-1 – 2018.01