4 Operation
INFORMATION
When the DHW tank mode is reheat, the risk for capacity
shortage and comfort problem is significant. In case of
frequent reheat operation, space heating/cooling function
is regularly interrupted.
In reheat mode, you can do the following:
You can...
Read out the desired reheat temperature.
Adjust the reheat temperature.
Condition:
is displayed on the DHW tank
temperature home page.
Activate the DHW tank booster mode.
Program a booster heater allowance schedule
to restrict when the booster heater can operate.
Example: Only allow the booster heater to
operate during the night.
(Only for field supplied domestic hot water
pump for secondary return)
Program a domestic hot water pump schedule
to determine when to turn ON and OFF the pump.
When turned ON, the pump runs and makes sure
hot water is instantly available at the tap. To save
energy, only turn ON the pump during periods of
the day when instant hot water is necessary.
See also:
"4.5.5 Using the DHW tank temperature home page" on page 13
"4.5.6 Using the DHW tank booster mode" on page 13
"4.7 Preset values and schedules" on page 16
4.5.3

Scheduled mode

In scheduled mode ( ), the DHW  tank produces hot water
corresponding to a schedule. The best time to allow the tank to
produce hot water is at night, because the space heating demand is
lower.
Example:
T t
1
2
60°C
50°C
40°C
15°C
00:00
07:00
T
DHW tank temperature
t
t
Time
▪ Initially, the DHW  tank temperature is the same as the
temperature of the domestic water entering the DHW  tank
(example: 15°C).
▪ At 00:00 the DHW tank is programmed to heat up the water to a
preset value (example: Storage comfort = 60°C).
▪ During the morning, you consume hot water and the DHW  tank
temperature decreases.
▪ At 14:00 the DHW tank is programmed to heat up the water to a
preset value (example: Storage eco = 50°C). Hot water is
available again.
User reference guide
12
Location
DHW tank
temperature
home page
Menu structure
4
3
5
t
14:00
21:00
▪ During the afternoon and evening, you consume hot water again
and the DHW tank temperature decreases again.
▪ At 00:00 the next day, the cycle repeats.
In scheduled mode, you can do the following:
You can...
Read out the active or next scheduled desired
temperature.
Overrule the active or next scheduled desired
temperature.
Condition:
is displayed on the DHW tank
temperature home page.
Activate the DHW tank booster mode.
Select a DHW tank temperature schedule.
Program a DHW tank temperature schedule.
Define preset values that are used by the
DHW tank temperature schedule.
Program a booster heater allowance schedule
to restrict when the booster heater can operate.
Example: Only allow the booster heater to
operate during the night.
(Only for field supplied domestic hot water
pump for secondary return)
Program a domestic hot water pump schedule
to determine when to turn ON and OFF the pump.
When turned ON, the pump runs and makes sure
hot water is instantly available at the tap. To save
energy, only turn ON the pump during periods of
the day when instant hot water is necessary.
See also:
"4.5.5 Using the DHW tank temperature home page" on page 13
"4.5.6 Using the DHW tank booster mode" on page 13
"4.7 Preset values and schedules" on page 16
4.5.4

Scheduled + reheat mode

In scheduled + reheat mode (   ), the domestic hot water control is
the same as in scheduled mode. However, when the DHW  tank
temperature drops below a preset value (=reheat tank temperature –
hysteresis value; example: 35°C), the DHW  tank heats up until it
reaches the reheat set point (example: 45°C). This ensures that a
minimum amount of hot water is available at all times.
Example:
T t
1
2
60°C
50°C
45°C
35°C
15°C
00:00
07:00
T
DHW tank temperature
t
t
Time
In scheduled + reheat mode, you can do the following:
You can...
Do the same things as in scheduled mode.
EBLQ+EDLQ011~016CAV3+W1 + EK(2)CB07CAV3 +
Daikin Altherma low temperature monobloc
Location
DHW tank
temperature
home page
Menu structure
3
4
5
t
14:00
21:00
Location
EKMBUHCA3V3+9W1
4P522035-1 – 2018.01