Altherma low temperature monobloc
Hide thumbs Also See for Altherma EBLQ016CAV3:
Table of Contents

Advertisement

2 Press
or
to adjust. Example:
INFORMATION
In case of weather dependency, an offset value can be
modified.
4.4.10
External room thermostat control - About
external room thermostat control
External room thermostat control means that you control the
following:
▪ Room temperature on the external thermostat control
▪ Leaving water temperature on the user interface (Daikin)
To control the leaving water temperature, you can do the following:
You can...
Read out the desired leaving water
temperature.
Adjust the desired leaving water
temperature.
Only change this if the desired room
temperature cannot be reached.
See also:
"4.4.6 Room thermostat control - Using the leaving water
temperature home pages" on page 9
4.4.11
External room thermostat control - Using
external room thermostat control
To adjust the leaving water temperature (main)
1 Go to the main leaving water temperature home page (LWT
main).
2 Press
or
to adjust. Example:
To adjust the leaving water temperature
(additional)
1 Go to the additional leaving water temperature home page
(LWT add).
2 Press
or
to adjust. Example:
INFORMATION
In case of weather dependency, an offset value can be
modified.
4.5

Domestic hot water control

4.5.1

About domestic hot water control

Depending on the DHW  tank mode (installer setting), you use a
different domestic hot water control:

▪ Reheat mode

▪ Scheduled mode
▪ Scheduled + reheat mode
EBLQ+EDLQ011~016CAV3+W1 + EK(2)CB07CAV3 +
EKMBUHCA3V3+9W1
Daikin Altherma low temperature monobloc
4P522035-1 – 2018.01
45°C 47°C
Location
Leaving water
temperature home
pages (main +
additional)
35°C 37°C
45°C 47°C
CAUTION
The booster heater permission schedule is used to restrict
or allow booster heater operation based on a weekly
program.
Advice:
In
disinfection function, at least allow the booster heater (by
the weekly program) for minimum 4 hours starting from the
scheduled start-up of disinfection. If the booster heater is
restricted during disinfection, this function will NOT be
successful and the applicable warning AH will be
generated.
INFORMATION
In case of error code AH and no interruption of the
disinfection function occurred due to domestic hot water
tapping, following actions are recommended:
▪ When the Domestic hot water > Type > Reheat or
Reheat + sched. is selected, it is recommended to
program the start-up of the disinfection function at least
4  hours later than the last expected large hot water
tapping. This start-up can be set by installer settings
(disinfection function).
▪ When the Domestic hot water > Type > Scheduled only
is selected, it is recommended to program a Storage
eco 3  hours before the scheduled start-up of the
disinfection function to preheat the tank.
To determine which DHW tank mode you are using (method 1)
Check the installer settings table filled in by the installer.
To determine which DHW tank mode you are using (method 2)
Prerequisite: User profile = Detailed.
1 Go to the DHW tank temperature home page (Tank).
2 Check which icons are displayed:
If... is displayed
Reheat mode
Scheduled mode
Scheduled + reheat mode
 
4.5.2
Reheat mode
In reheat mode ( ),the DHW  tank continuously heats up to the
temperature shown on the DHW  tank temperature home page
(example: 50°C).
T t
1
60°C
50°C
40°C
15°C
00:00
07:00
T
DHW tank temperature
t
t
Time
INFORMATION
There is a risk of space heating (cooling) capacity
shortage/comfort problem (in case of frequent domestic hot
water operation, frequent and long space heating/cooling
interruption will happen) when selecting [6‑0D]=0 ([A.4.1]
Domestic hot water Type=Reheat only) in case of a
domestic hot water tank without an internal booster heater.
4 Operation
order
to
avoid
unsuccessful
Then the DHW tank mode =...
3
2
4
t
14:00
21:00
User reference guide
11