To set the overrule period
Prerequisite: You switched the permission level to Advanced end
user.
1 Go to [7.2]:
> User settings > Temperature lock.
2 Select a value and press
▪ Permanent
▪ hours (2, 4, 6, 8)
3.3.2
Room thermostat control - Using the
leaving water temperature home pages
INFORMATION
The leaving water is the water that is sent to the heat
emitters. The desired leaving water temperature is set by
your installer in accordance with the heat emitter type.
Example: Underfloor heating is designed for lower leaving
water
temperature
than
convectors and/or fan coil units. You only have to adjust
leaving water temperature settings in case of problems.
For more information about the leaving water temperature, see the
user reference guide.
3.4

Domestic hot water control

NOTICE
Disinfection mode. Even if you turn OFF domestic hot
water operation via the DHW tank temperature home page
(Tank), disinfection mode will remain active.
3.4.1

Instant DHW (no tank installed)

Not applicable for Switzerland
When there is a demand for hot water tapping, the boiler provides
DHW instantly.
Using the instant DHW home page
Not applicable for Switzerland
Depending on the user profile, the user interface gives you either a
basic or a detailed home page.
User profile = Basic
Tue
01:03
DHW
44°C
Desired temperature
To adjust the instant DHW temperature
1 Go to the instant DHW home page.
2 Press
or
to adjust the instant DHW temperature (DHW).
The instant DHW set point temperature may NOT be below 40°C.
3.4.2

Tank

The following modes are only applicable if a tank is installed and are
set by the installer.
Reheat mode
In reheat mode ( ),the DHW  tank continuously heats up to the
temperature shown on the DHW  tank temperature home page
(example: 50°C).
CHYHBH05+08AF
Daikin Altherma R Hybrid
4P471757-1C – 2020.10
:
radiators
and
heat  pump
User profile = Detailed
Tue
01:03
44°C
DHW
Desired temperature
T t
1
60°C
50°C
40°C
15°C
00:00
07:00
T
Domestic hot water tank temperature
t
t
Time
INFORMATION
When the DHW tank mode is reheat, the risk for capacity
shortage and comfort problem is significant. In case of
frequent reheat operation, space heating function is
regularly interrupted.
Scheduled mode
In scheduled mode ( ), the DHW  tank produces hot water
corresponding to a schedule. The best time to allow the tank to
produce hot water is at night, because the space heating demand is
lower.
Example:
T t
1
2
60°C
50°C
40°C
15°C
00:00
07:00
T
Domestic hot water tank temperature
t
t
Time
Scheduled + reheat mode
In scheduled + reheat mode (   ), the domestic hot water control is
the same as in scheduled mode. However, when the DHW  tank
temperature drops below a preset value (=reheat tank temperature –
hysteresis value; example: 35°C), the DHW  tank heats up until it
reaches the reheat set point (example: 45°C). This ensures that a
minimum amount of hot water is available at all times.
Example:
T t
1
2
60°C
50°C
45°C
35°C
15°C
00:00
07:00
T
DHW tank temperature
t
t
Time
Storage comfort
60°C
Storage eco
50°C
Reheat
45°C
35°C
Reheat tank temperature – hysteresis value
3 Operation
3
2
4
t
14:00
21:00
4
3
5
t
14:00
21:00
3
4
5
14:00
21:00
t
Operation manual
5